A Reference System for Neuroanatomical Localization on Functional Reconstructed Cerebral Images
- 1 January 1989
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 13 (1), 174-178
- https://doi.org/10.1097/00004728-198901000-00045
Abstract
The correlation of anatomical with functional brain images is of critical importance for data analysis. We have designed and tested a reference system method that provides accurate localization of neuroanatomy on functional brain images. The method differs from prior techniques using headholding devices in that it does not require head fixation and is noninvasive. The reference system can be quickly, accurately, and reproducibly applied to the patient''s head with respect to the surface anatomy of the head. The reference system is easily adaptable to multiple imaging modalities. The reference system is implemented with the aid of a computer algorithm that reconstructs the anatomic images into a new image matching a selected functional image. Accuracy and reproducibility of placement of the reference system was demonstrated by the application of the system on multiple subjects by two independent observers. The use of this method provides accurate correlation between functional and anatomical brain images.This publication has 11 references indexed in Scilit:
- Proportional Localization System for Anatomical Interpretation of Cerebral Computed TomogramsJournal of Computer Assisted Tomography, 1985
- A Stereotactic Method of Anatomical Localization for Positron Emission TomographyJournal of Computer Assisted Tomography, 1985
- Computer Assisted Mapping in Quantitative Analysis of Cerebral Positron Emission TomogramsJournal of Computer Assisted Tomography, 1985
- Evaluation of the Performance Characteristics of the PC 4600 Positron Emission TomographJournal of Computer Assisted Tomography, 1984
- A Computerized System for the Elastic Matching of Deformed Radiographic Images to Idealized Atlas ImagesJournal of Computer Assisted Tomography, 1983
- An Inexpensive Video Patient Repositioning System for Use With Transmission and Emission Computed TomographsJournal of Computer Assisted Tomography, 1982
- Computer Assisted Analysis of Tomographic Images of the BrainJournal of Computer Assisted Tomography, 1981
- Head Fixation Device for Reproducible Position Alignment in Transmission CT and Positron Emission TomographyJournal of Computer Assisted Tomography, 1981
- Stereotaxic computerized tomography with a GE 8800 scannerJournal of Neurosurgery, 1980
- A computerized tomography-computer graphics approach to stereotaxic localizationJournal of Neurosurgery, 1979