Role of small calibre chest tube drainage for iatrogenic pneumothorax.
Open Access
- 1 October 1990
- Vol. 45 (10), 748-749
- https://doi.org/10.1136/thx.45.10.748
Abstract
A 2 mm Teflon catheter was used as a chest tube in 28 patients with iatrogenic pneumothorax. Frequent aspirations through the catheter were performed in 16 of the patients. In the remaining 12 patients the catheter was connected to a one way flutter valve. The treatment was successful in 27 of the 28 patients--one patient required a large calibre chest tube. The mean drainage time was 48 hours. The small catheter technique is superior to the use of a large intercostal drain as it is much less traumatic and troublesome. The small calibre chest tube with a one way valve is recommended as a safe and easy technique.This publication has 11 references indexed in Scilit:
- Treatment of Pneumothoraces Utilizing Small Caliber Chest TubesChest, 1988
- Transthoracic needle aspiration: use of a small chest tube to treat pneumothoraxAmerican Journal of Roentgenology, 1987
- Treatment of pneumothorax by simple aspiration.Thorax, 1983
- Emergency treatment of pneumothorax. A simple catheter technique for use in the radiology department.1970
- EMERGENCY TREATMENT OF PNEUMOTHORAXAmerican Journal of Roentgenology, 1970
- Valve Drainage of the Pleural CavityDiseases of the Chest, 1968
- The management of spontaneous pneumothorax.Thorax, 1966
- Management of spontaneous pneumothorax.1966
- Treatment of Spontaneous PneumothoraxThorax, 1962