Analysis of Solids, Liquids, and Biological Tissues Using Solids Probe Introduction at Atmospheric Pressure on Commercial LC/MS Instruments
Top Cited Papers
- 14 October 2005
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (23), 7826-7831
- https://doi.org/10.1021/ac051470k
Abstract
Direct analysis of samples using atmospheric pressure ionization (API) provides a more rapid method for analysis of volatile and semivolatile compounds than vacuum solids probe methods and can be accomplished on commercial API mass spectrometers. With only a simple modification to either an electrospray (ESI) or atmospheric pressure chemical ionization (APCI) source, solid as well as liquid samples can be analyzed in seconds. The method acts as a fast solids/liquid probe introduction as well as an alternative to the new direct analysis in real time (DART) and desorption electrospray ionization (DESI) methods for many compound types. Vaporization of materials occurs in the hot nitrogen gas stream flowing from an ESI or APCI probe. Ionization of the thermally induced vapors occurs by corona discharge under standard APCI conditions. Accurate mass and mass-selected fragmentation are demonstrated as is the ability to obtain ions from biological tissue, currency, and other objects placed in the path of the hot nitrogen stream.Keywords
This publication has 8 references indexed in Scilit:
- Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray IonizationScience, 2004
- Trace Analysis of Organics in Air by Corona Discharge Atmospheric Pressure Ionization Using an Electrospray Ionization InterfaceEuropean Journal of Mass Spectrometry, 2004
- Direct Analysis of Semivolatile Organic Compounds in Air by Atmospheric Pressure Chemical Ionization Mass SpectrometryAnalytical Chemistry, 2001
- Use of Humidified Air in Optimizing APCI−MS Response in Breath AnalysisJournal of Agricultural and Food Chemistry, 2000
- Electrospray interface for liquid chromatographs and mass spectrometersAnalytical Chemistry, 1985
- Selected ion monitoring for multicomponent analyses by computer control of accelerating voltage and magnetic fieldAnalytical Chemistry, 1975
- Atmospheric pressure ionization (API) mass spectrometry. Formation of phenoxide ions from chlorinated aromatic compoundsAnalytical Chemistry, 1975
- New picogram detection system based on a mass spectrometer with an external ionization source at atmospheric pressureAnalytical Chemistry, 1973