Problems with the hydroxyapatite orbital implant: experience with 250 consecutive cases.
Open Access
- 1 September 1994
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 78 (9), 702-706
- https://doi.org/10.1136/bjo.78.9.702
Abstract
The coral derived hydroxyapatite sphere is a popular, integrated orbital implant designed to provide improved motility of the ocular prosthesis following enucleation. Although the implant has rapidly become widely used by ophthalmologists, little information is available regarding the problems of this technique in a large series of cases. Experience with 250 consecutive cases of hydroxyapatite orbital implant use was reviewed and the problems of the implants and their management investigated specifically. The reasons for enucleation included uveal melanoma (157 cases), retinoblastoma (70 cases), blind painful eye (22 cases), and intraocular medulloepithelioma (one case). Earlier treatment to the eye was performed before enucleation in 47 cases and included repair of ruptured globe (17 cases), plaque radiotherapy (18 cases), external beam radiotherapy (six cases), and others (six cases). During a mean of 23 months' follow up (range 6-40 months), there have been no recognisable cases of orbital haemorrhage related to the implant, and no cases of implant extrusion or implant migration. There was one case of presumed orbital infection (culture negative) that resolved with intravenous antibiotics and the implant was retained within the orbit. Other problems included conjunctival thinning in eight cases managed by observation and prosthesis adjustment, and conjunctival erosion in four cases managed by combinations of scleral patch graft, conjunctival flap, and prosthesis adjustment. The conjunctival erosion was caused by a poorly fitting prosthesis in three cases and wound dehiscence in one case. The problem rate in eyes receiving prior radiotherapy or surgery was not increased. The hydroxyapatite integrated orbital implant is a well tolerated motility implant without the high rate of extrusion and infection seen with other motility implants. The prosthesis fit may contribute to the tolerance of the implant.Keywords
This publication has 22 references indexed in Scilit:
- Use of the Hydroxyapatite Ocular Implant in the Pediatric PopulationArchives of Ophthalmology (1950), 1994
- Modified Enucleation via Lateral Orbitotomy for Choroidal Melanoma with Orbital ExtensionOphthalmic Plastic & Reconstructive Surgery, 1992
- Hydroxyapatite Orbital Implant After Enucleation Experience With Initial 100 Consecutive CasesArchives of Ophthalmology (1950), 1992
- Ocular TuberculosisPublished by American Medical Association (AMA) ,1991
- Coralline Hydroxyapatite as an Ocular ImplantOphthalmology, 1991
- Surgical correction of the Vertically Deficient ChinPlastic and Reconstructive Surgery, 1988
- Bone Formation within Porous Hydroxylapatite Implants in Human Periodontal DefectsThe Journal of Periodontology, 1986
- Experimental Ridge Augmentation With Porous Hydroxyapatite ImplantsJournal of Dental Research, 1983
- Extraskeletal of a Porous Hydroxyapatite CeramicJournal of Dental Research, 1982
- Bone Regeneration Within a Coralline Hydroxyapatite ImplantPlastic and Reconstructive Surgery, 1979