Anatomical Localization for PET Using MR Imaging
- 1 May 1990
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 14 (3), 418-426
- https://doi.org/10.1097/00004728-199005000-00019
Abstract
Accurate localization of an imaging plane of interest is often needed prior to a positron emission tomographic (PET) study. We have developed a simple method for accurate and reproducible selection of an imaging plane for PET using magnetic resonance (MR) imaging. This method is useful when optimal sampling of specific brain structures, such as small subcortical nuclei, or when a specific imaging angle is required for the PET study. An external localizing device, consisting of a series of tubes visible on MR, is affixed to an individually fitted thermoplastic mask. This mask system is worn by the patient during both the MR and PET studies. A plane of interest is planned from the sagittal MR image and defined by its relation to the localizing device and to the MR scanner's “landmark” or reference position. This plane is transferred to the mask by means of a calibrated alignment laser. The coplanar acquisition of MR and PET images allows individualized analysis of brain structure–function relationships. Phantom studies demonstrated the accuracy and reproducibility of imaging plane selection by this method to be within 1 mm and 1°. Application of the localization protocol in a human subject is also presented.Keywords
This publication has 16 references indexed in Scilit:
- Accuracy of stereotaxic localisation using MRI and CT.Journal of Neurology, Neurosurgery & Psychiatry, 1986
- Proportional Localization System for Anatomical Interpretation of Cerebral Computed TomogramsJournal of Computer Assisted Tomography, 1985
- Imaging Opiate Receptors in the Human Brain by Positron TomographyJournal of Computer Assisted Tomography, 1985
- A Stereotactic Method of Anatomical Localization for Positron Emission TomographyJournal of Computer Assisted Tomography, 1985
- Analysis of Emission Tomographic Scan Data: Limitations Imposed by Resolution and BackgroundJournal of Computer Assisted Tomography, 1984
- A Computerized System for the Elastic Matching of Deformed Radiographic Images to Idealized Atlas ImagesJournal of Computer Assisted Tomography, 1983
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1982
- Quantitation in Positron Emission Computed Tomography: 5. Physical–Anatomical EffectsJournal of Computer Assisted Tomography, 1981
- Head Fixation Device for Reproducible Position Alignment in Transmission CT and Positron Emission TomographyJournal of Computer Assisted Tomography, 1981
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1979