Contact Lens Drying and Visual Performance: The Vision Cycle with Contact Lenses
- 1 June 2002
- journal article
- research article
- Published by Wolters Kluwer Health in Optometry and Vision Science
- Vol. 79 (6), 381-388
- https://doi.org/10.1097/00006324-200206000-00012
Abstract
The purpose of this study was to measure the effect of precontact lens tear film break-up on visual performance. Four asymptomatic soft contact lens wearers had contrast sensitivity measured by a temporal, two-alternative, force choice paradigm combined with a self-paced methods of limits. Stimuli were vertically orientated sine wave gratings (0.5 to 14 cycles per degree [cpd] presented for 16.67 ms. Contrast sensitivity was measured before precontact lens tear break-up by a stimuli presented 2 s after the blink. A post-tear layer break-up measurement taken with the stimuli presented after break-up had been observed by the use of a video camera attached to a Tearscope. Contrast sensitivity was found to be reduced following precontact lens tear film break-up for stimuli of 4, 6, and 10 cpd; the data approached significance at 14 cpd. Further reductions in contrast sensitivity were observed for one subject when measurements were continued for 4 s following break-up. Contrast sensitivity is significantly reduced for middle to high spatial frequencies when the precontact lens tear film dries and breaks up. The combination of observations of visual performance immediately following the blink (from earlier experiments) and measurements following tear film break-up in this experiment allows description of a “vision cycle” for contact lens wearers in the interval between blinks. It is suggested that break-up of the precontact lens tear film could account for the complaints of intermittent blurred vision in some contact lens wearers and may provide a stimulus to blinking in these individuals.Keywords
This publication has 37 references indexed in Scilit:
- Responses of Contact Lens Wearers to a Dry Eye SurveyOptometry and Vision Science, 2000
- Soft Contact Lens-Induced Longitudinal Spherical Aberration and Its Effect on Contrast SensitivityOptometry and Vision Science, 1990
- Visual Decrement with Deposit Accumulation on HEMA Contact LensesOptometry and Vision Science, 1988
- Effect of Hydrogel Lens Wear on Contrast SensitivityOptometry and Vision Science, 1988
- Effect of target contrast and luminance on soft contact lens and spectacle visual performanceCurrent Eye Research, 1988
- Changes in Contrast Sensitivity during the First Hour of Soft Lens WearOptometry and Vision Science, 1986
- Effects of Soft Contact Lenses on Contrast SensitivityOptometry and Vision Science, 1985
- AN ANALYSIS OF VISUAL PERFORMANCE WITH SOFT CONTACT LENS AND SPECTACLE CORRECTIONOphthalmic and Physiological Optics, 1985
- Contrast Sensitivities Through Spectacles and Soft Contact LensesOptometry and Vision Science, 1981
- CHANGES IN THE CONTRAST SENSITIVITY FUNCTION INDUCED BY CONTACT LENS WEAROptometry and Vision Science, 1975