Advances in refractive surgery: microkeratome and femtosecond laser flap creation in relation to safety, efficacy, predictability, and biomechanical stability
- 1 August 2006
- journal article
- review article
- Published by Wolters Kluwer Health in Current Opinion in Opthalmology
- Vol. 17 (4), 368-372
- https://doi.org/10.1097/01.icu.0000233957.88509.2d
Abstract
Methods of flap creation have changed over the years from the evolution of the mechanical microkeratome to the introduction of the IntraLase femtosecond laser keratome, both of which have different mechanisms of action to create corneal resections. Previous studies report the advantages and disadvantages of the mechanical microkeratome and the IntraLase femtosecond laser. The critical components in laser in-situ keratomileusis surgery remain the same, however: safety, efficiency, predictability, and biomechanical stability. Keratoectasia and flap efficiency remain a constant safety concern in laser in-situ keratomileusis surgery. Unexpectedly thick flaps as well as variable thickness continue to be a concern with safety in relation to microkeratome technology. Epithelial preservation, flap complications, and newer issues such as Transient Light Sensitivity Syndrome are safety concerns of flap creation. Improved outcomes with regards to vision, induced astigmatism, induced higher-order aberrations, and enhancement rates are seen to favor predictability of femtosecond technologies over the microkeratome. Recent biomechanical studies show improved healing with femtosecond laser flap creation compared with blade-assisted flap creation. The aim of this review is to summarize the key components for both the microkeratome and the femtosecond laser and to update on the recent advances reported on these topics.Keywords
This publication has 23 references indexed in Scilit:
- Transient light sensitivity after femtosecond laser flap creation: Clinical findings and managementJournal of Cataract & Refractive Surgery, 2006
- Thin flap laser in situ keratomileusis: Flap dimensions with the Moria LSK-One manual microkeratome using the 100-μm headJournal of Cataract & Refractive Surgery, 2005
- Randomized prospective clinical study comparing induced aberrations with IntraLase and Hansatome flap creation in fellow eyesJournal of Cataract & Refractive Surgery, 2005
- Corneal flap thickness and topography changes induced by flap creation during laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2005
- Comparison of the IntraLase femtosecond laser and mechanical keratomes for laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2004
- Unexpected flap thickness in laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2003
- Corneal ectasia induced by laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2001
- Posterior corneal curvature changes after myopic laser in situ keratomileusisOphthalmology, 2001
- Iatrogenic keratectasia after laser in situ keratomileusis for less than −4.0 to −7.0 diopters of myopiaJournal of Cataract & Refractive Surgery, 2000
- Posterior corneal surface topographic changes after laser in situ keratomileusis are related to residual corneal bed thicknessOphthalmology, 1999