Reconstruction of a ring applicator using CT imaging: impact of the reconstruction method and applicator orientation
- 30 July 2007
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (16), 4893-4904
- https://doi.org/10.1088/0031-9155/52/16/012
Abstract
The purpose of this study is to investigate whether the method of applicator reconstruction and/or the applicator orientation influence the dose calculation to points around the applicator for brachytherapy of cervical cancer with CT-based treatment planning. A phantom, containing a fixed ring applicator set and six lead pellets representing dose points, was used. The phantom was CT scanned with the ring applicator at four different angles related to the image plane. In each scan the applicator was reconstructed by three methods: (1) direct reconstruction in each image (DR), (2) reconstruction in multiplanar reconstructed images (MPR) and (3) library plans, using pre-defined applicator geometry (LIB). The doses to the lead pellets were calculated. The relative standard deviation (SD) for all reconstruction methods was less than 3.7% in the dose points. The relative SD for the LIB method was significantly lower (p < 0.05) than for the DR and MPR methods for all but two points. All applicator orientations had similar dose calculation reproducibility. Using library plans for applicator reconstruction gives the most reproducible dose calculation. However, with restrictive guidelines for applicator reconstruction the uncertainties for all methods are low compared to other factors influencing the accuracy of brachytherapy.Keywords
This publication has 14 references indexed in Scilit:
- Cervical brachytherapy utilizing ring applicator: Comparison of standard and conformal loadingInternational Journal of Radiation Oncology*Biology*Physics, 2005
- Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancerInternational Journal of Radiation Oncology*Biology*Physics, 2005
- Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group☆ (I): concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTVRadiotherapy and Oncology, 2005
- Proposed guidelines for image-based intracavitary brachytherapy for cervical carcinoma: Report from Image-Guided Brachytherapy Working GroupInternational Journal of Radiation Oncology*Biology*Physics, 2004
- Inter fraction variations in rectum and bladder volumes and dose distributions during high dose rate brachytherapy treatment of the uterine cervix investigated by repetitive CT-examinationsRadiotherapy and Oncology, 2001
- Variations of intracavitary applicator geometry during multiple HDR brachytherapy insertions in carcinoma cervix and its influence on reporting as per ICRU report 38Radiotherapy and Oncology, 2001
- Comparison of traditional low-dose-rate to optimized and nonoptimized high-dose-rate tandem and ovoid dosimetryInternational Journal of Radiation Oncology*Biology*Physics, 2001
- Rectal doses in intracavitary brachytherapy of gynecological malignancies: comparison of two dosimetric methodsRadiotherapy and Oncology, 2001
- Comparison of radiography- and computed tomography-based treatment planning in cervix cancer in brachytherapy with specific attention to some quality assurance aspectsRadiotherapy and Oncology, 2001
- Inter-observer variation in delineation of bladder and rectum contours for brachytherapy of cervical cancerRadiotherapy and Oncology, 2000