Directional velocity estimation using a spatio-temporal encoding technique based on frequency division for synthetic transmit aperture ultrasound
- 7 August 2006
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 53 (7), 1289-1299
- https://doi.org/10.1109/tuffc.2006.1665077
Abstract
This paper investigates the possibility of flow estimation using spatio-temporal encoding of the transmissions in synthetic transmit aperture imaging (STA). The spatial encoding is based on a frequency division approach. In STA, a major disadvantage is that only a single transmitter (denoting single transducer element or a virtual source) is used in every transmission. The transmitted acoustic energy will be low compared to a conventional focused transmission in which a large part of the aperture is used. By using several transmitters simultaneously, the total transmitted energy can be increased. However, to focus the data properly, the signals originating from the different transmitters must be separated. To do so, the pass band of the transducer is divided into a number of subbands with disjoint spectral support. At every transmission, each transmitter is assigned one of the subbands. In receive, the signals are separated using a simple filtering operation. To attain high axial resolution, broadband spectra must be synthesized for each of the transmitters. By multiplexing the different waveforms on different transmitters over a number of transmissions, this can be accomplished. To further increase the transmitted energy, the waveforms are designed as linear frequency modulated signals. Therefore, the full excitation amplitude can be used during most of the transmission. The method has been evaluated for blood velocity estimation for several different velocities and incident angles. The program Field II was used. A 128-element transducer with a center frequency of 7 MHz was simulated. The 64 transmitting elements were used as the transmitting aperture and 128 elements were used as the receiving aperture. Four virtual sources were created in every transmission. By beamforming lines in the flow direction, directional data were extracted and correlated. Hereby, the velocity of the blood was estimated. The pulse repetition frequency was 16 kHz.Keywords
This publication has 20 references indexed in Scilit:
- Experimental investigation of synthetic aperture flow angle estimationPublished by SPIE-Intl Soc Optical Eng ,2005
- Use of modulated excitation signals in medical ultrasound. Part I: basic concepts and expected benefitsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2005
- Use of modulated excitation signals in medical ultrasound. Part II: design and performance for medical imaging applicationsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2005
- Use of modulated excitation signals in medical ultrasound. Part III: high frame rate imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2005
- Coded excitation for diagnostic ultrasound: a system developer's perspectiveIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2005
- Statistical analysis and time correlation processes applied to velocity measurement (blood flow)Published by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- Sparse array imaging with spatially-encoded transmitsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- An effective coded excitation scheme based on a predistorted FM signal and an optimized digital filterPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1999
- Coded excitation system for improving the penetration of real-time phased-array imaging systemsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1992
- Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1992