Flow modeling in a novel non‐perfusion conical bioreactor
- 10 January 2007
- journal article
- research article
- Published by Wiley in Biotechnology & Bioengineering
- Vol. 97 (5), 1291-1299
- https://doi.org/10.1002/bit.21327
Abstract
We have developed a bioreactor vessel design which has the advantages of simplicity and ease of assembly and disassembly, and with the appropriately determined flow rate, even allows for a scaffold to be suspended freely regardless of its weight. This article reports our experimental and numerical investigations to evaluate the performance of a newly developed non‐perfusion conical bioreactor by visualizing the flow through scaffolds with 45° and 90° fiber lay down patterns. The experiments were conducted at the Reynolds numbers (Re) 121, 170, and 218 based on the local velocity and width of scaffolds. The flow fields were captured using short‐time exposures of 60 µm particles suspended in the bioreactor and illuminated using a thin laser sheet. The effects of scaffold fiber lay down pattern and Reynolds number were obtained and correspondingly compared to results obtained from a computational fluid dynamics (CFD) software package. The objectives of this article are twofold: to investigate the hypothesis that there may be an insufficient exchange of medium within the interior of the scaffold when using our non‐perfusion bioreactor, and second, to compare the flows within and around scaffolds of 45° and 90° fiber lay down patterns. Scaffold porosity was also found to influence flow patterns. It was therefore shown that fluidic transport could be achieved within scaffolds with our bioreactor design, being a non‐perfusion vessel. Fluid velocities were generally same of the same or one order lower in magnitude as compared to the inlet flow velocity. Additionally, the 90° fiber lay down pattern scaffold was found to allow for slightly higher fluid velocities within, as compared to the 45° fiber lay down pattern scaffold. This was due to the architecture and pore arrangement of the 90° fiber lay down pattern scaffold, which allows for fluid to flow directly through (channel‐like flow). Biotechnol. Bioeng. 2007; 97: 1291–1299.Keywords
This publication has 34 references indexed in Scilit:
- Bioreactors for Tissue Engineering: Focus on Mechanical Constraints. A Comparative ReviewTissue Engineering, 2006
- A CFD level-set method for soft tissue growth: theory and fundamental equationsJournal of Biomechanics, 2005
- Technical Note: Design of a Flow Perfusion Bioreactor System for Bone Tissue-Engineering ApplicationsTissue Engineering, 2003
- Cell differentiation by mechanical stressThe FASEB Journal, 2001
- TISSUE ENGINEERING BIOREACTORSPublished by Elsevier ,2000
- A numerical study of steady viscous flow past a circular cylinderJournal of Fluid Mechanics, 1980
- Experimental determination of the main features of the viscous flow in the wake of a circular cylinder in uniform translation. Part 1. Steady flowJournal of Fluid Mechanics, 1977
- Wake characteristics of two-dimensional perforated plates normal to an air-streamJournal of Fluid Mechanics, 1971
- The steady separated flow past a circular cylinder at large Reynolds numbersJournal of Fluid Mechanics, 1965
- LXXXVI. On eddies in airJournal of Computers in Education, 1923