Spatial-temporal filter effect in a computer model study of ventricular fibrillation / Räumlicher und zeitlicher Filtereffekt in einer Computermodellstudie zum Herzkammerflimmern
- 1 January 2008
- journal article
- Published by Walter de Gruyter GmbH in Biomedizinische Technik/Biomedical Engineering
- Vol. 53 (4), 163-173
- https://doi.org/10.1515/bmt.2008.025
Abstract
Prediction of countershock success from ventricular fibrillation (VF) ECG is a major challenge in critical care medicine. Recent findings indicate that stable, high frequency mother rotors are one possible mechanism maintaining VF. A computer model study was performed to investigate how epicardiac sources are reflected in the ECG. In the cardiac tissues of two computer models - a model with cubic geometry and a simplified torso model with a left ventricle - a mother rotor was induced by increasing the potassium rectifier current. On the epicardium, the dominant frequency (DF) map revealed a constant DF of 23 Hz (cubic model) and 24.4 Hz (torso model) in the region of the mother rotor, respectively. A sharp drop of frequency (3-18 Hz in the cubic model and 12.4-18 Hz in the torso model) occurred in the surrounding epicardial tissue of chaotic fibrillatory conduction. While no organized pattern was observable on the body surface of the cubic model, the mother rotor frequency can be identified in the anterior surface of the torso model because of the chosen position of the mother rotor in the ventricle (shortest distance to the body surface). Nevertheless, the DFs were damped on the body surfaces of both models (4.6-8.5 Hz in the cubic model and 14.4-16.4 Hz in the torso model). Thus, it was shown in this computer model study that wave propagation transforms the spatial low pass filtering of the thorax into a temporal low pass. In contrast to the resistive-capacitive low pass filter formed by the tissue, this spatial-temporal low pass filter becomes effective at low frequencies (tens of Hertz). This effect damps the high frequency components arising from the heart and it hampers a direct observation of rapid, organized sources of VF in the ECGs, when in an emergency case an artifact-free recording is not possible.Keywords
This publication has 26 references indexed in Scilit:
- Prediction of countershock success using single features from multiple ventricular fibrillation frequency bands and feature combinations using neural networksResuscitation, 2007
- A Comparison of Monodomain and Bidomain Reaction-Diffusion Models for Action Potential Propagation in the Human HeartIEEE Transactions on Biomedical Engineering, 2006
- Evidence for Multiple Mechanisms in Human Ventricular FibrillationCirculation, 2006
- The effect of torso impedance on epicardial and body surface potentials: a modeling studyIEEE Transactions on Biomedical Engineering, 2003
- Removal of cardiopulmonary resuscitation artifacts from human ECG using an efficient matching pursuit-like algorithmIEEE Transactions on Biomedical Engineering, 2002
- On modeling the Wilson terminal in the boundary and finite element methodIEEE Transactions on Biomedical Engineering, 2002
- A computer model of human atria with reasonable computation load and realistic anatomical propertiesIEEE Transactions on Biomedical Engineering, 2001
- Spiral Waves in Two-Dimensional Models of Ventricular Muscle: Formation of a Stationary CoreBiophysical Journal, 1998
- A model of the ventricular cardiac action potential. Depolarization, repolarization, and their interaction.Circulation Research, 1991
- A simulation study of the effects of torso inhomogeneities on electrocardiographic potentials, using realistic heart and torso models.Circulation Research, 1983