Dual-Function Microanalytical Device by In Situ Photolithographic Grafting of Porous Polymer Monolith: Integrating Solid-Phase Extraction and Enzymatic Digestion for Peptide Mass Mapping
- 29 August 2003
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (20), 5328-5335
- https://doi.org/10.1021/ac034108j
Abstract
Microfluidic devices with a dual function containing both a solid-phase extractor and an enzymatic microreactor have been prepared, and their operation has been demonstrated. The devices were fabricated from a 25-mm-long porous poly(butyl methacrylate-co-ethylene dimethacrylate) monolith prepared within a 50-μm-i.d. capillary. This capillary with a pulled 9−12-μm needle tip was used as a nanoelectrospray emitter coupling the device to a mass spectrometer. Photografting with irradiation through a mask was then used to selectively functionalize a 20-mm-long portion of the monolith, introducing reactive poly(2-vinyl-4,4-dimethylazlactone) chains to enable the subsequent attachment of trypsin, thereby creating an enzymatic microreactor with high proteolytic activity. The other 5 mm of unmodified hydrophobic monolith served as micro solid-phase extractor (μSPE). The dual-function devices were used in two different flow directions; concentration of myoglobin that was absorbed from its dilute solution, followed by elution and digestion or digestion, followed by concentration. Operations in both directions afforded equal sequence coverage. Different volumes of myoglobin solution ranging from 2 to 20 μL were loaded on the device. Very high sequence coverages of almost 80% were achieved for the highest loading. Despite the very short length of the extractor unit, the device operated in the digest−solid-phase extraction direction also enabled the separation of peaks that mostly contained undigested protein and peptides.Keywords
This publication has 50 references indexed in Scilit:
- Surface Functionalization of Thermoplastic Polymers for the Fabrication of Microfluidic Devices by Photoinitiated GraftingAdvanced Functional Materials, 2003
- Chemistry and technology of 2‐alkenyl azlactonesJournal of Polymer Science Part A: Polymer Chemistry, 2001
- Microreactor and electrochemical detectors fabricated using Si and EPON SU-8Sensors and Actuators B: Chemical, 2000
- Chip-based nanovials for tryptic digest and capillary electrophoresisAnalytica Chimica Acta, 1999
- Photoinitiated modifications of polymers: photocrosslinking, surface photografting and photolaminationMaterials Research Innovations, 1998
- Comparison of the properties of trypsin immobilized on 2 Celite™ derivativesJournal of Biotechnology, 1997
- “Molded” Macroporous Poly(glycidyl methacrylate-co-trimethylolpropane trimethacrylate) Materials with Fine Controlled Porous Properties: Preparation of Monoliths Using Photoinitiated PolymerizationChemistry of Materials, 1997
- A Microscale Electrospray Interface for Online, Capillary Liquid Chromatography/Tandem Mass Spectrometry of Complex Peptide MixturesAnalytical Chemistry, 1995
- Continuous rods of macroporous polymer as high-performance liquid chromatography separation mediaAnalytical Chemistry, 1992
- Graft copolymer of polyacrylamide and natural rubber produced by means of ultraviolet lightJournal of Polymer Science, 1957