Abstract
Red cell survival was studied in 21 patients following homograft replacement of the aortic valve. Autologous cells labelled with 51Cr were used. The T½ 51Cr varied between 24 and 34 days, with only one patient below the normal limit of normal variations. The absence of haemolysis was confirmed by other haematological studies, including estimation of reticulocytes, serum lactic dehydrogenase, and urinary haemosiderin. Haptoglobin levels were low in most of the patients studied. In contrast to prosthetic valves there was no haemolysis in patients with regurgitation around or through the homograft valve.Keywords
This publication has 21 references indexed in Scilit:
- Homograft replacement of the aortic valve. A critical reviewProgress in Cardiovascular Diseases, 1969
- Chronic haemolysis following insertion of ball valve prostheses.Heart, 1968
- Mechanical destruction of erythrocytes by incompetent aortic valvular prosthesesAmerican Heart Journal, 1966
- Homograft valve replacement for aortic valve disease.Thorax, 1965
- Red Cell Survival in Patients with Aortic Valve DiseaseThorax, 1965
- Medical problems of aortic valve replacementProgress in Cardiovascular Diseases, 1965
- INTRAVASCULAR HÆMOLYTIC ANÆMIA AFTER AORTIC-VALVE REPLACEMENTThe Lancet, 1964
- Aortic ReplacementCirculation, 1963
- HOMOGRAFT REPLACEMENT OF THE AORTIC VALVEThe Lancet, 1962
- A SIMPLE METHOD FOR THE DETERMINATION OF SERUM HAPTOGLOBINSJournal of Clinical Pathology, 1960