Abstract
In October 1976 the Zero Gradient Synchrotron (ZGS) became the first high energy proton synchrotron to use charge exchange injection in routine operations. Conversion to H- injection has been very successful, yielding record high beam intensities within the first month of use and normal (> 90%) operating efficiencies within the second month. This report discusses briefly the history of H- at the ZGS, the hardware uniquely associated with charge exchange injection and our operational experience during the first two months of H- injection.

This publication has 5 references indexed in Scilit: