Selective control of muscle activation with a multipolar nerve cuff electrode
- 1 July 1993
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 40 (7), 640-653
- https://doi.org/10.1109/10.237694
Abstract
Acute experiments were performed on adult cats to study selective activation of medial gastrocnemius, soleus, tibialis anterior, and extensor digitorium longus with a cuff electrode. A spiral nerve cuff containing twelve dot electrodes was implanted around the sciatic nerve, and evoked muscle twitch forces were recorded in six experiments. Spatially isolated dot electrodes in four geometries (monopolar, longitudinal tripolar, tripolar with four common anodes, and two parallel tripoles) were combined with transverse field steering current(s) from an anode(s) located 180 degrees around from the cathode(s) to activate different regions of the nerve trunk. A selectivity index was used to construct recruitment curves for a muscle with the optimal degree of selectivity. Physiological responses were correlated with the anatomical structure of the sciatic nerve by identifying the nerve fascicles innervating the four muscles, and by determining the relative positions of the electrodes and the nerve fascicles. The results indicated that the use of transverse field steering current improved selectivity. The relative performance of the various electrode arrangements is discussed.Keywords
This publication has 15 references indexed in Scilit:
- Selective Activation Of Peripheral Nerve Fascicles: Use Of Field Steering CurrentsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2005
- A nerve cuff technique for selective excitation of peripheral nerve trunk regionsIEEE Transactions on Biomedical Engineering, 1990
- A spiral nerve cuff electrode for peripheral nerve stimulationIEEE Transactions on Biomedical Engineering, 1988
- Current Density Profiles of Surface Mounted and Recessed Electrodes for Neural ProsthesesIEEE Transactions on Biomedical Engineering, 1987
- Recruitment properties of monopolar and bipolar epimysial electrodesAnnals of Biomedical Engineering, 1986
- Scanning electron microscopy of chronically stimulated platinum intracochlear electrodesBiomaterials, 1985
- Selective activation of muscles using peripheral nerve electrodesMedical & Biological Engineering & Computing, 1985
- AC impedance of the perineurium of the frog sciatic nerveBiophysical Journal, 1984
- The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve StimulationIEEE Transactions on Biomedical Engineering, 1983
- Modulation of Muscle Force by Recruitment During Intramuscular StimulationIEEE Transactions on Biomedical Engineering, 1980