GASTRIC-EMPTYING MEASUREMENTS - DELAYED AND COMPLEX EMPTYING PATTERNS WITHOUT APPROPRIATE CORRECTION

  • 1 January 1985
    • journal article
    • research article
    • Vol. 26 (10), 1206-1210
Abstract
Anteriorly acquired and geometric mean corrected gastric emptying curves of solids and liquid isotopic-labeled meals were compared in 37 subjects given 61 meals of three different sizes. Anterior data alone consistently and significantly underestimated solid-phase gastric emptying rates with all meal sizes when compared to geometric mean acquired data. However, with liquids there were only slight differences between anterior and anterior and posterior geometric mean corrected emptying-rates. The difference probably reflects greater attenuation of the 140 kev photon of 99mTc compared to the 247 keV photon of 111In. With anterior data alone, an apparent early delay in emptying of solids was present with all meal sizes and the resultant emptying curves were nonlinear in shape. Geometric mean correction resulted in the linearization of the solid-phase emptying curves and essentially eliminated the apparent delay in emptying or lag phase noted with the anterior data alone. Based on our results, geometric mean correction techniques are necessary for accurate assessment of radioisotopic-labeled solid meals.