Presence of viable mould propagules in indoor air in relation to house damp and outdoor air
- 1 April 1992
- Vol. 47 (2PART1), 83-91
- https://doi.org/10.1111/j.1398-9995.1992.tb05093.x
Abstract
The presence of viable mould propagules in indoor air was investigated using the N6‐Andersen sampler in combination with DG18‐agar, in relation to house damp (characterized with a checklist) and in relation to the presence of moulds in outdoor air. The first part of the study was conducted in 46 houses in the autumn of 1987, the second part in 84 houses in May 1989. Further, in the second part, the results obtained with settlement plates (OPD) were compared with those obtained with the N6‐Andersen sampler. The number of CFU/m3 in the indoor and outdoor air varied widely. A large variety of mould genera and species was isolated. Species of Cladosporium, Penicillium and Wallemia predominated. The variability in time was high and the reproducibility of the measurements in terms of CFU/m3 and of species isolated was only moderate. The low predictive value of these measurements limits their use in epidemiological studies of the relationship between exposure to moulds and respiratory symptoms. Overall, the geometric mean concentration was somewhat higher outdoors than indoors. However, the clear differences found between the number of CFU/m3 belonging to different mould species in in‐ and outdoor air show that the presence of viable mould propagules in indoor air is not simply a reflection of the presence of moulds in outdoor air. The presence of moulds in indoor air was only weakly related to house damp as characterized by the checklist. High, statistically significant correlations were found between the CFU yield obtained with the OPD and the CFU/m3 yield obtained with the N6‐Andersen sampler. However, the number of species isolated with the OPD was significantly lower than that obtained with the N6‐Andersen sampler.Keywords
This publication has 19 references indexed in Scilit:
- Respiratory symptoms in damp homesAllergy, 1989
- Damp housing and childhood asthma: validation of reporting of symptoms.BMJ, 1988
- Species Identification of Airborne Molds and Its Significance for the Detection of Indoor PollutionJAPCA, 1987
- Indirect health effects of relative humidity in indoor environments.Environmental Health Perspectives, 1986
- Asthma and the indoor environment: Assessment of the health implications of high indoor air humidityEnvironment International, 1986
- Diagnosis of house dust mite allergy in asthmatic children: what constitutes a positive history?Journal of Allergy and Clinical Immunology, 1983
- Fungi as a Cause of Allergic DiseaseAllergy, 1979
- Identification and Prevalence of Culturable Mesophilic Microfungi in House Dust from 100 Danish Homes.Allergy, 1978
- IDENTIFICATION AND QUANTITATION OF INDOOR AIRBORNE MICRO‐FUNGI DURING 12 MONTHS FROM 44 DANISH HOMESAllergy, 1972
- ALLERGY IN 7000 TWIN PAIRSAllergy, 1971