Enantioselective Sensors Based on Antibody-Mediated Nanomechanics
- 19 April 2003
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (10), 2342-2348
- https://doi.org/10.1021/ac034031z
Abstract
The use of microfabricated cantilevers as bioaffinity sensors was investigated. Since many bioaffinity interactions involve proteins as receptors, we conducted studies of the magnitude, kinetics, and reversibility of surface stresses caused when common proteins interact with microcantilevers (MCs) with nanostructured (roughened) gold surfaces on one side. Exposure of nanostructured, unfunctionalized MCs to the proteins immunoglobulin G and bovine serum albumin (BSA) resulted in reversible large tensile stresses, whereas MCs with smooth gold surfaces on one side produced reversible responses that were considerably smaller and compressive. The response magnitude for nanostructured MCs exposed to BSA is shown to be concentration dependent, and linear calibration over the range of 1−200 mg/L is demonstrated. Stable, reusable protein bioaffinity phases based on unique enantioselective antibodies are created by covalently linking monoclonal antibodies to nanostructured MC surfaces. The direct (label-free) stereoselective detection of trace amounts of an important class of chiral analytes, the α-amino acids, was achieved based on immunomechanical responses involving nanoscale bending of the cantilever. The temporal response of the cantilever (Δ deflection/Δ time) is linearly proportional to the analyte concentration and allows the quantitative determination of enantiomeric purity up to an enantiomeric excess of 99.8%. To our knowledge, this is the first demonstration of chiral discrimination using highly scalable microelectromechanical systems.Keywords
This publication has 22 references indexed in Scilit:
- Peer Reviewed: Microcantilever Transducers: A new Approach in Sensor TechnologyPublished by American Chemical Society (ACS) ,2002
- Nanostructured Microcantilevers with Functionalized Cyclodextrin Receptor Phases: Self-Assembled Monolayers and Vapor-Deposited FilmsAnalytical Chemistry, 2002
- Characterisation of an antibody coated microcantilever as a potential immuno-based biosensorBiosensors and Bioelectronics, 2002
- Photomechanical chemical microsensorsSensors and Actuators B: Chemical, 2001
- Enhanced chemi-mechanical transduction at nanostructured interfacesChemical Physics Letters, 2001
- Gold Nano-Structures for Transduction of Biomolecular Interactions into Micrometer Scale MovementsBiomedical Microdevices, 2001
- Selectivity of chemical sensors based on micro-cantilevers coated with thin polymer filmsAnalytica Chimica Acta, 2000
- Translating Biomolecular Recognition into NanomechanicsScience, 2000
- Adsorption-induced surface stress and its effects on resonance frequency of microcantileversJournal of Applied Physics, 1995
- Vapor Detection Using Resonating MicrocantileversAnalytical Chemistry, 1995