The use of a fibrin tissue sealant during laparoscopic partial nephrectomy
Open Access
- 25 March 2004
- journal article
- Published by Wiley in BJU International
- Vol. 93 (6), 813-817
- https://doi.org/10.1111/j.1464-410x.2003.04742.x
Abstract
The use of a fibrin tissue sealant in laparoscopic partial nephrectomy is described by authors from Chapel Hill. They used it in 15 patients after electrocauterization and argon-beam coagulation; it was helpful in haemotasis and in preventing urinary leak. OBJECTIVE To assess the feasibility and efficacy of commercially available fibrin tissue sealant as a haemostatic agent and collecting-system sealant during hand-assisted laparoscopic partial nephrectomy (LPN). PATIENTS AND METHODS Fifteen consecutive patients underwent LPN for enhancing renal masses suspicious for renal cell carcinoma via a transperitoneal approach and with the use of a hand-assistance device. Monopolar electrocauterization and argon-beam coagulation were initially used to slow bleeding from the resection site. Through a laparoscopic applicator, TisseelTM fibrin sealant (Baxter Inc., Deerfield, IL) was applied to the transected partial nephrectomy bed while the surgeon's hand maintained adequate compression and partial haemostasis. No further haemostatic measures were required in any patient; the patients were evaluated for acute and delayed bleeding or urinary extravasation. RESULTS In all cases electrocauterization and argon-beam coagulation followed by the application of Tisseel was successful in obtaining strict haemostasis of the surgical bed, with no evidence of bleeding during or after surgery on immediate and extended follow-up. In addition, there was no evidence during or after surgery of any urinary leak. There were no immediate or delayed complications in any of the patients; a short-term outpatient follow-up (12–60 weeks) revealed no additional problems. CONCLUSIONS Conventional haemostatic measures of electrocauteriztion and argon-beam coagulation combined with commercial fibrin sealant allows successful haemostasis during LPN. In addition to haemostatic properties, fibrin sealants appear to have sealing properties that may help to prevent complications of urinary leakage by helping to seal or close the small defects in the urinary collecting system. The use of this compound may facilitate the ability of the urological laparoscopist during LPN.Keywords
This publication has 25 references indexed in Scilit:
- Minimally Invasive Management of the Small Renal Tumor: Review of Laparoscopic Partial Nephrectomy and Ablative TechniquesJournal of Endourology, 2002
- Laparoscopic Partial Nephrectomy with a Novel Electrosurgical Snare in a Porcine ModelJournal of Endourology, 2002
- Clinical Use of the Holmium:YAG Laser in Laparoscopic Partial NephrectomyJournal of Endourology, 2002
- Endoloop-Assisted Laparoscopic Partial NephrectomyJournal of Endourology, 2002
- LAPAROSCOPIC PARTIAL NEPHRECTOMY WITH A MICROWAVE TISSUE COAGULATOR FOR SMALL RENAL TUMORJournal of Urology, 2001
- Hand-Assisted Laparoscopic Partial NephrectomyJournal of Endourology, 2001
- Nephron-sparing surgeryCurrent Urology Reports, 2001
- Extraperitoneal laparoscopic dismembered fibrin‐glued pyeloplasty: medium‐term resultsBritish Journal of Urology, 1997
- Recent Advances in Laparoscopic Partial Nephrectomy: Comparative Study of Electrosurgical Snare Electrode and Ultrasound DissectionJournal of Endourology, 1997
- The Use of Fibrin Sealant in Nephron Sparing Surgery for Renal TumorsPublished by Springer Nature ,1994