Quantification of Cerebral Perfusion With “Real-Time” Contrast-Enhanced Ultrasound
- 20 November 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 104 (21), 2582-2587
- https://doi.org/10.1161/hc4601.099400
Abstract
Background No noninvasive technique is currently capable of “real-time” assessment and monitoring of cerebral blood flow (CBF). We hypothesized that cerebral perfusion could be accurately measured and monitored in “real time” with contrast-enhanced ultrasound (CEU). Methods and Results Cerebral perfusion was assessed in 9 dogs through a craniotomy with CEU at baseline and during hypercapnia and hypocapnia while normoxia was maintained. Cerebral microvascular blood volume (A), microbubble velocity (β), and blood flow (A×β) were calculated from time-versus–acoustic intensity relations. Compared with baseline, hypercapnia and hypocapnia significantly increased and decreased CBF, respectively, as measured by CEU. These changes in blood flow were mediated by changes in both A and β. A good correlation was found between A×β derived from CEU and CBF measured by radiolabeled microspheres (y=0.67x−0.04, r=0.91, PConclusions Changes in both cerebral microvascular blood volume and red blood cell velocity can be accurately assessed with CEU. Thus, CEU has the potential for bedside measurement and monitoring of cerebral perfusion in real time in patients with craniotomies or burr holes.Keywords
This publication has 18 references indexed in Scilit:
- Power Doppler harmonic imaging: A feasibility study of a new technique for the assessment of myocardial perfusionAmerican Heart Journal, 2000
- Pulse-inversion contrast harmonic imaging: ultrasonographic assessment of cerebral perfusionThe Lancet, 2000
- Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging TechniquesJournal of Cerebral Blood Flow & Metabolism, 1999
- Better Outcome for Women Compared With Men Undergoing Coronary RevascularizationCirculation, 1998
- Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion?Journal of the American College of Cardiology, 1998
- Effects of Hypoxia and Hypercapnia on Capillary Flow Velocity in the Rat Cerebral CortexMicrovascular Research, 1997
- Decreased Heterogeneity of Capillary Plasma Flow in the Rat Whisker-Barrel Cortex during Functional HyperemiaJournal of Cerebral Blood Flow & Metabolism, 1996
- Albunex: A Safe and Effective Commercially Produced Agent for Myocardial Contrast EchocardiographyJournal of the American Society of Echocardiography, 1989
- The Aging Human Cerebral Cortex: A Stereological Characterization of Changes in the Capillary NetJournal of Gerontology, 1979
- Blood flow measurements with radionuclide-labeled particlesProgress in Cardiovascular Diseases, 1977