Enhancement of Sensitivity and Resolution of Surface-Enhanced Laser Desorption/Ionization Time-of-Flight Mass Spectrometric Records for Serum Peptides Using Time-Series Analysis Techniques
- 1 January 2005
- journal article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 51 (1), 65-74
- https://doi.org/10.1373/clinchem.2004.037283
Abstract
Background: Measurement of peptide/protein concentrations in biological samples for biomarker discovery commonly uses high-sensitivity mass spectrometers with a surface-processing procedure to concentrate the important peptides. These time-of-flight (TOF) instruments typically have low mass resolution and considerable electronic noise associated with their detectors. The net result is unnecessary overlapping of peaks, apparent mass jitter, and difficulty in distinguishing mass peaks from background noise. Many of these effects can be reduced by processing the signal using standard time-series background subtraction, calibration, and filtering techniques. Methods: Surface-enhanced laser desorption/ionization (SELDI) spectra were acquired on a PBS II instrument from blank, hydrophobic, and IMAC-Cu ProteinChip® arrays (Ciphergen Biosystems, Inc.) incubated with calibration peptide mixtures or pooled serum. TOF data were recorded after single and multiple laser shots at different positions. Correlative analysis was used for time-series calibration. Target filters were used to suppress noise and enhance resolution after baseline removal and noise rescaling. Results: The developed algorithms compensated for the electronic noise attributable to detector overload, removed the baseline caused by charge accumulation, detected and corrected mass peak jitter, enhanced signal amplitude at higher masses, and improved the resolution by using a deconvolution filter. Conclusions: These time-series techniques, when applied to SELDI-TOF data before any peak identification procedure, can improve the data to make the peak identification process simpler and more robust. These improvements may be applicable to most TOF instrumentation that uses analog (rather than counting) detectors.Keywords
This publication has 21 references indexed in Scilit:
- Reproducibility of SELDI-TOF protein patterns in serum: comparing datasets from different experimentsBioinformatics, 2004
- Quality Control and Peak Finding for Proteomics Data Collected from Nipple Aspirate Fluid by Surface-Enhanced Laser Desorption and IonizationClinical Chemistry, 2003
- A comprehensive approach to the analysis of matrix‐assisted laser desorption/ionization‐time of flight proteomics spectra from serum samplesProteomics, 2003
- Mass Spectrometry in Structural BiologyPublished by Wiley ,2000
- Proteinchip® surface enhanced laser desorption/ionization (SELDI) mass spectrometry: a novel protein biochip technology for detection of prostate cancer biomarkers in complex protein mixturesProstate Cancer and Prostatic Diseases, 1999
- Ion formation in MALDI mass spectrometryMass Spectrometry Reviews, 1998
- Determination of monoisotopic masses and ion populations for large biomolecules from resolved isotopic distributionsJournal of the American Society for Mass Spectrometry, 1995
- Improvement of signal reproducibility and matrix/comatrix effects in MALDI analysisAnalytical Chemistry, 1995
- Fourier transform ion cyclotron resonance mass spectrometryPublished by Elsevier ,1990
- Time-of-Flight Mass SpectrometersPublished by Springer Nature ,1966