Rapid and Sensitive Detection of BRCA1/2 Mutations in a Diagnostic Setting: Comparison of Two High-Resolution Melting Platforms
- 1 June 2008
- journal article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 54 (6), 982-989
- https://doi.org/10.1373/clinchem.2007.098764
Abstract
High-resolution melting is an emerging technique for detection of nucleic acid sequence variations. Developments in instrumentation and saturating intercalating dyes have made accurate high-resolution melting analysis possible and created opportunities to use this technology in diagnostic settings. We evaluated 2 high-resolution melting instruments for screening BRCA1 and BRCA2 mutations. To cover the complete coding region and splice sites, we designed 112 PCR amplicons (136-435 bp), amplifiable with a single PCR program. LCGreen Plus was used as the intercalating dye. High-resolution melting analysis was performed on the 96-well Lightscanner (Idaho Technology Inc.) and the 96-well LightCycler 480 (Roche) instruments. We evaluated sensitivity by analyzing 212 positive controls scattered over almost all amplicons and specificity by blind screening of 22 patients for BRCA1 and BRCA2. In total, we scanned 3521 fragments. All 212 known heterozygous sequence variants were detected on the Lightscanner by analysis on normal sensitivity setting. On the LightCycler 480, the standard instrument sensitivity setting of 0.3 had to be increased to 0.7 to detect all variants, decreasing the specificity to 95.9% (vs 98.7% for the Lightscanner). Previously, we screened BRCA1/2 by direct sequencing of the large exon 11 and denaturing gel gradient electrophoresis (DGGE) for all other coding exons. Since the introduction of high-resolution melting, our turnaround time has been one third of that with direct sequencing and DGGE, as post-PCR handling is no longer required and the software allows fast analyses. High-resolution melting is a rapid, cost-efficient, sensitive method simple enough to be readily implemented in a diagnostic laboratory.Keywords
This publication has 18 references indexed in Scilit:
- Detection of Factor VIII Gene Mutations by High-Resolution Melting AnalysisClinical Chemistry, 2007
- Expanded Instrument Comparison of Amplicon DNA Melting Analysis for Mutation Scanning and GenotypingClinical Chemistry, 2007
- Mutation Scanning the GJB1 Gene with High-Resolution Melting Analysis: Implications for Mutation Scanning of Genes for Charcot-Marie-Tooth DiseaseClinical Chemistry, 2007
- A DGGE system for comprehensive mutation screening ofBRCA1andBRCA2: application in a Dutch cancer clinic settingHuman Mutation, 2006
- Amplicon DNA Melting Analysis for Mutation Scanning and Genotyping: Cross-Platform Comparison of Instruments and DyesClinical Chemistry, 2006
- Sensitivity and Specificity of Single-Nucleotide Polymorphism Scanning by High-Resolution Melting AnalysisClinical Chemistry, 2004
- BRCA1 and BRCA2 germline mutation spectrum and frequencies in Belgian breast/ovarian cancer familiesBritish Journal of Cancer, 2004
- High-Resolution Genotyping by Amplicon Melting Analysis Using LCGreenClinical Chemistry, 2003
- The complete BRCA2 gene and mutations in chromosome 13q-linked kindredsNature Genetics, 1996
- A Strong Candidate for the Breast and Ovarian Cancer Susceptibility Gene BRCA1Science, 1994