Medical applications of dust-free rooms. 3. Use in an animal care laboratory.

  • 1 August 1969
    • journal article
    • Vol. 18 (2), 142-6
Abstract
Bacterial air sampling in an animal care laboratory showed that dense aerosols are generated during cage changing and cage cleaning. Reyniers and Andersen sampling showed that the airborne bacteria numbered 50 to 200 colony-forming units (CFU)/ft(3) of air. Of the viable particles collected by Andersen samplers, 78.5% were larger than 5.5 mum. A low velocity laminar air flow system composed of high-efficiency particulate air (HEPA) filters and a ceiling distribution system maintained the number of airborne viable particles at low levels, generally less than 2 CFU/ft(3). Vertical air flow of 15 ft/min significantly reduced the rate of airborne infection by a strain of Proteus mirabilis. Other factors shown to influence airborne infection included type of cage utilized, the use of bedding, the distance between cages, and the number of animals per cage.