A simplified method for deuterium/hydrogen isotope ratio measurements on water samples of biological origin
- 1 July 1993
- journal article
- research article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 22 (7), 383-387
- https://doi.org/10.1002/bms.1200220704
Abstract
Equilibration of hydrogen gas with the water in a variety of biological sample materials was carried out in Vacutainers using platinum-on-alumina catalyst physically isolated from the liquid water. The equilibration takes 3 days at room temperature—much slower than with catalysts which float on the water surface—but this reduces the short-term temperature sensitivity of the procedure, and the inexpensive materials used allow convenient disposal of biologically contaminated samples after analysis. The slow equilibration also allows time for complete exchange with water contained in a complex sample matrix such as plant stems or soil without the need for prior isolation of the water sample. The method has particular application in studies of human total body water where repeated studies can be carried out over a short time period without the need to wait for the previous dose to wash out. Water turnover rates from total diurnal energy expenditure studies measured by this method were not significantly different from those obtained by the zinc reduction method.This publication has 9 references indexed in Scilit:
- Improvements in the gaseous hydrogen-water equilibration technique for hydrogen isotope-ratio analysisAnalytical Chemistry, 1991
- Changes in body composition and energy expenditure after six weeks' growth hormone treatment.Archives of Disease in Childhood, 1991
- Hydrogen isotope analysis of natural waters using an H2-water equilibration method: A special implication to brinesChemical Geology: Isotope Geoscience section, 1988
- In vivo isotope-fractionation factors and the measurement of deuterium- and oxygen-18-dilution spaces from plasma, urine, saliva, respiratory water vapor, and carbon dioxideThe American Journal of Clinical Nutrition, 1988
- Determination of deuterium level in biological fluids by isotope ratio mass spectrometryJournal of Mass Spectrometry, 1987
- Deuterium and oxygen-18 measurements on microliter samples of urine, plasma, saliva, and human milkThe American Journal of Clinical Nutrition, 1987
- Isotope Exchange Technique for Preparation of Hydrogen Gas in Mass Spectrometry D/H Analysis of Natural WatersAnalytical Sciences, 1986
- Multi-sample conversion of water to hydrogen by zinc for stable isotope determinationAnalytical Chemistry, 1985
- Hydrogen-isotope composition of leaf water in C3 and C4 plants: its relationship to the hydrogen-isotope composition of dry matterPlanta, 1985