Abstract
A flow cytometric method has been developed that uses phase-sensitive detection to separate signals from simultaneous fluorescence emissions in cells labeled with fluorochromes having different fluorescence decay lifetimes. By CHO cells were stained with propidium iodide (PI) and fluorescein isothiocyanate (FITC). These dyes bind to DNA and protein and the fluorescence lifetimes of the bound dyes are 15.0 and 3.6 ns, respectively. Cells were analyzed as they passed through a modulated (sinusoidal) laser excitation beam. Fluorescence was measured using only a long pass filter to block scattered laser excitation light and a single photomultiplier tube detector. The fluorescence detector output signals were processed by dual-channel phase-sensitive detection electronics and the phase-resolved Pland FITC signals were displayed as frequency distribution histograms and bivariate plots. By shifting the phase of one detector channel reference signal by π/2 + ψ1 degrees and the phase of the other detector channel reference signal by −π/2 + ψ2 degrees, where ψ1 and ψ2 are the phase shifts associated with the PI and FITC lifetimes, the PI and FITC signals were separately resolved at their respective phase-sensitive detector outputs. This technology is also applicable to suppressing background interferences caused by cellular autofluorescence, unbound/free dye, nonspecific dye binding, and Raman and Rayleigh scattering.Keywords
This publication has 17 references indexed in Scilit:
- Improved multilaser/multiparameter flow cytometer for analysis and sorting of cells and particlesReview of Scientific Instruments, 1991
- A modular detector for flow cytometric multicolor fluorescence measurementsCytometry, 1987
- Laser Doppler velocimetry for particle size determination by light scatter within the sheath flow cuvetteAnalytical Chemistry, 1987
- Enhancement of Luminescence and Raman Spectorscopy by Phase-Resolved Background SuppressionAnalytical Chemistry, 1985
- Atlas of Fluorescence Spectra and Lifetimes of Dyes Attached to ProteinAnalytical Letters, 1985
- Phase-resolved fluorescence spectroscopyAnalytical Chemistry, 1984
- The Measurement and Analysis of Heterogeneous Emissions by Multifrequency Phase and Modulation FluorometryApplied Spectroscopy Reviews, 1984
- Phase-sensitive fluorescence spectroscopy: A new method to resolve fluorescence lifetimes or emission spectra of components in a mixture of fluorophoresJournal of Biochemical and Biophysical Methods, 1981
- RAPID, SIMULTANEOUS MEASUREMENT OF DNA, PROTEIN, AND CELL VOLUME IN SINGLE CELLS FROM LARGE MAMMALIAN CELL POPULATIONSThe Journal of cell biology, 1973
- Der zeitliche Intensit tsverlauf von intermittierend angeregter ResonanzstrahlungThe European Physical Journal A, 1933