Platelet storage for 7 days in second‐generation blood bags
- 4 March 1986
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 26 (2), 131-135
- https://doi.org/10.1046/j.1537-2995.1986.26286152900.x
Abstract
Plastic storage bags designed to optimize O2 and CO2 transfer to preserve platelets for 7 days prior to transfusion were studied in vivo and in vitro. Platelets stored 7 days in second-generation CLX bags were compared to platelets stored 3 days in standard (CL-3861) 3-day storage bags and platelets transfused within 24 hours of collection. The CLX bags maintained concentrate pH at a mean of 6.85 .+-. 0.03 (SEM) after 7 days, while in standard bags after 3 days of storage, the mean pH was 6.46 .+-. 0.03. A smaller proportion of platelets stored 7 days in CLX bags were discarded because of a pH less than 6.0 compared to those stored 3 days in CL-3861 bags (10 vs 21%). Poststorage pH showed strong correlation with concentrate platelet count and weak correlation with concentrate white cell count in both bag types. There was no significant difference in the mean corrected platelet count increments between platelets stored 7 days in second generation CLX bags and those stored 3 days in CL-3861 bags (10,000 and 12,200 at 1 hour, and 7000 and 7500 at 24 hours, respectively) following transfusion to 16 thrombocytopenic recipients. However, transfusion of fresh platelets achieved mean corrected increments at both 1 and 24 hours posttransfusion that were higher than seen with either group of stored platelets (20,100 at 1 hour at 10,800 at 24 hours). Platelets can be stored 7 days in second-generation CLX blood bags with results comparable to those of platelets stored 3 days in standard bags.This publication has 15 references indexed in Scilit:
- Lymphocytotoxic antibody is a predictor of response to random donor platelet transfusionAmerican Journal of Hematology, 1983
- Lack of adverse effect of transportation on room temperature stored platelet concentratesTransfusion, 1982
- Factors Influencing Changes in pH during Storage of Platelet Concentrates at 20–24°C1,2Vox Sanguinis, 1982
- Transfusion experience with platelet concentrates stored for 24 to 72 hours at 22° CTransfusion, 1982
- In vitro Measurements of Platelet Concentrates Stored at 4 and 22°C: Correlation with Posttransfusion Platelet Viability and FunctionVox Sanguinis, 1981
- Platelet glycolysis in platelet storage. IV. The effect of supplemental glucose and adenineTransfusion, 1980
- Preparation and Storage of Platelet Concentrates: II. STORAGE VARIABLES INFLUENCING PLATELET VIABILITY AND FUNCTIONBritish Journal of Haematology, 1976
- Optimum Centrifugation Conditions for the Preparation of Platelet and Plasma ProductsTransfusion, 1976
- A Study of Variables Affecting the Quality of Platelets Stored at “Room Temperature”Transfusion, 1975
- Detection and Quantitation of Bacteria in Platelet Products Stored at Ambient TemperatureTransfusion, 1973