An Improved Method for Automatic Segmentation of the Left Ventricle in Myocardial Perfusion SPECT
Open Access
- 21 January 2009
- journal article
- research article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 50 (2), 205-213
- https://doi.org/10.2967/jnumed.108.057323
Abstract
This study describes and validates a new method for automatic segmentation of left ventricular mass (LVM) in myocardial perfusion SPECT (MPS) images. This is important for estimating the size of a perfusion defect as percentage of the left ventricle. Methods: A total of 101 patients with known or suspected coronary artery disease underwent both rest and stress MPS and MRI. A new automated algorithm was trained in 20 patients (40 MPS studies) and tested in 81 patients (162 MPS studies). The algorithm, which segmented the left ventricle in the MPS images, is based on Dijkstra's algorithm and finds an optimal mid-mural line through the left ventricular wall. From this line, the endocardium and epicardium are identified on the basis of an individually estimated wall thickness and signal intensity. The algorithm was validated by comparing LVM in both stress and rest MPS, with LVM of the manually segmented left ventricle from MRI as the reference standard. For comparison, LVM was quantified using the software quantitative perfusion SPECT (QPS). Results: The mean difference ± SD in LVM between MPS and MRI was lower for the new method (6% ± 15% LVM) than for QPS (18% ± 19% LVM) for both mean difference (P < 0.001) and SD (P = 0.015). Linear regression analysis of LVM, comparing MPS and MRI, yielded R2 = 0.83 using the new method and R2 = 0.80 using QPS. Interstudy variability, measured as the coefficient of variance between rest MPS and stress MPS, was 6% for both the new method and QPS. Both the new algorithm and QPS systematically overestimated LVM in hearts with thin myocardium and underestimated LVM in hearts with thick myocardium. Conclusion: The new segmentation algorithm quantifies LVM with a significantly lower bias and variability than does the commercially available QPS software, when compared to manually segmented LVM by MRI. This makes the new algorithm an attractive method to use for estimating the size of the perfusion defect when expressing it as percentage of the left ventricle. This study shows that inaccurate estimation of wall thickness is the main source of error in automatic segmentation.This publication has 15 references indexed in Scilit:
- Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: validation of an elastic surface model approach in comparison to cardiac magnetic resonance imaging, 4D-MSPECT and QGSEuropean Journal of Nuclear Medicine and Molecular Imaging, 2007
- What Is the Optimal Clinical Technique for Measurement of Left Ventricular Volume After Myocardial Infarction? A Comparative Study of 3-Dimensional Echocardiography, Single Photon Emission Computed Tomography, and Cardiac Magnetic Resonance ImagingJournal of the American Society of Echocardiography, 2006
- Evaluation of left ventricular volumes and ejection fraction by automated gated myocardial SPECT versus cardiovascular magnetic resonanceClinical Physiology and Functional Imaging, 2005
- Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?European Heart Journal, 2004
- Reduction in Sample Size for Studies of Remodeling in Heart Failure by the Use of Cardiovascular Magnetic ResonanceJournal of Cardiovascular Magnetic Resonance, 2000
- Experimental validation of a new quantitative method for the analysis of infarct size by cardiac perfusion tomography (SPECT)The International Journal of Cardiovascular Imaging, 1993
- Effects of myocardial wall thickness on SPECT quantificationIEEE Transactions on Medical Imaging, 1990
- Thallium-201 single-photon emission computed tomographic estimates of left ventricular mass in patients with and without ischemic heart diseaseAmerican Heart Journal, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Determination of left ventricular mass using single-photon emission computed tomographyThe American Journal of Cardiology, 1985