Background: Definite size and shape of radiofrequency-induced ablations (RFAs) cannot be evaluated intraoperatively. Instead, surgeons choose a radiofrequency device that is supposed to cause a necrosis of a determined size greater than the malignant lesion. The aim of this study was to measure the variability of the induced necroses postoperatively and to define a reproducible ablation volume in human liver. Methods: In 24 patients, 34 RFA procedures were performed with single applications of the device. The deployment was 3 cm (n = 16), 4 cm (n = 5), or 5 cm (n = 13). The induced necroses were analyzed by volumetric reconstructions of computed tomography (CT) scans. Measured volumes were compared with the expected volumes. Furthermore, the shape of the necrosis was classified according to an index of the diameters. Results: The measured volumes of postoperative necroses were 14 ± 8 cm3 (deployment, 3 cm), 24 ± 12 cm3 (4 cm), and 45 ± 42 cm3 (5 cm). The diameter of a sphere fitted into the necroses reached 2.9 ± .5 cm (3 cm), 3.5 ± .7 cm (4 cm), and 4.1 ± 1.1 cm (5 cm), at P < .02, significantly smaller than the deployment. The classification of shapes yielded a spherical shape (n = 14), a teardrop shape (n = 13), or an irregular shape (n = 7). The energy consumption was 2.1 ± 1.5 kJ/cm3 (3 cm), 2.6 ± .5 kJ/cm3 (4 cm), or 3.5 ± 2.0 kJ/cm3 (5 cm). Conclusions: The diameter of RFA-induced liver necrosis is significantly smaller than expected from needle deployment, especially with full-needle deployment. The shape of the lesion differs in more than half of the cases from the anticipated spherical pattern. The upper limit for reproducible necrosis induction is a tumor diameter of 3.4 cm.Keywords
This publication has 14 references indexed in Scilit:
- Lesion progression with time and the effect of vascular occlusion following radiofrequency ablation of the liverBritish Journal of Surgery, 2003
- Radiofrequency Ablation in 447 Complex Unresectable Liver Tumors: Lessons LearnedAnnals of Surgical Oncology, 2003
- Radiofrequency ablation of the porcine liver with complete hepatic vascular occlusionAnnals of Surgical Oncology, 2002
- Treatment of hepatocellular carcinoma with radiofrequency ablation: Radiologic-histologic correlation during follow-up periodsHepatology, 2002
- Sonographically Observed Echogenic Response During Intraoperative Radiofrequency Ablation of Cirrhotic LiversAmerican Journal of Roentgenology, 2002
- Effect of Vascular Occlusion on Radiofrequency Ablation of the LiverAmerican Journal of Roentgenology, 2001
- Radiofrequency Liver AblationAmerican Journal of Roentgenology, 2001
- Creation of Radiofrequency Lesions in a Porcine ModelAmerican Journal of Roentgenology, 2000
- Radiofrequency Ablation Lesions in a Pig Liver ModelJournal of Surgical Research, 1999
- Radiofrequency Ablation of Porcine Liver In VivoAnnals of Surgery, 1998