Inter-scan reproducibility of coronary calcium measurement using Multi Detector-Row Computed Tomography (MDCT)
Open Access
- 11 April 2007
- journal article
- research article
- Published by Springer Nature in European Journal of Epidemiology
- Vol. 22 (4), 235-243
- https://doi.org/10.1007/s10654-007-9123-4
Abstract
To assess inter-scan reproducibility of coronary calcium measurements obtained from Multi Detector-Row CT (MDCT) images and to evaluate whether this reproducibility is affected by different measurement protocols, slice thickness, cardiovascular risk factors and/or technical variables. Cross-sectional study with repeated measurements. The study population comprised 76 healthy women. Coronary calcium was assessed in these women twice in one session using 16-MDCT (Philips Mx 8000 IDT 16). Images were reconstructed with 1.5 mm slice thickness and 3.0 mm slice thickness. The 76 repeated scans were scored. The Agatston score, a volume measurement and a mass measurement were assessed. Reproducibility was determined by estimation of mean, absolute, relative difference, the weighted kappa value for agreement and the Intra-class correlation coefficient (ICCC). Fifty-five participants (72.4%) had a coronary calcification of more than zero in Agatston (1.5 mm slice thickness). The reproducibility of coronary calcium measurements between scans in terms of ranking was excellent with Intra-class correlation coefficients of >0.98, and kappa values above 0.80. The absolute difference in calcium score between scans increased with increasing calcium levels, indicating that measurement error increases with increasing calcium levels. However, no relation was found between the mean difference in scores and calcium levels, indicating that the increase in measurement error is likely to result in random misclassification in calcium score. Reproducibility results were similar for 1.5 mm slices and for 3.0 mm slices, and equal for Agatston, volume and mass measurements. Inter-scan reproducibilility of measurement of coronary calcium using images from MDCT is excellent, irrespective of slice thickness and type of calcium parameter.Keywords
This publication has 22 references indexed in Scilit:
- Coronary artery calcification and cardiovascular risk factors: impact of the analytic approachAtherosclerosis, 2004
- Coronary Artery Calcium Quantification at Multi–Detector Row Helical CT versus Electron-Beam CTRadiology, 2004
- Electron beam CT versus helical CT scans for assessing coronary calcification: current utility and future directionsAmerican Heart Journal, 2003
- A Rosetta Stone for Coronary Calcium Risk Stratification: Agatston, Volume, and Mass Scores in 11,490 IndividualsAmerican Journal of Roentgenology, 2003
- Coronary Artery Calcium: Accuracy and Reproducibility of Measurements with Multi–Detector Row CT—Assessment of Effects of Different Thresholds and Quantification MethodsRadiology, 2003
- Imaging of Coronary CalciumJournal of Thoracic Imaging, 2001
- Electron Beam Computed Tomographic Coronary Calcium Scanning: A Review and Guidelines for Use in Asymptomatic PersonsMayo Clinic Proceedings, 1999
- Detection of coronary calcification with electron-beam computed tomography: Evaluation of interexamination reproducibility and comparison of three image-acquisition protocolsAmerican Heart Journal, 1996
- Quantification of coronary artery calcium using ultrafast computed tomographyJournal of the American College of Cardiology, 1990
- Significance of calcification of the coronary arteriesThe American Journal of Cardiology, 1970