Abstract
Automated processes designed to sterilize reusable medical instruments use heat and low-temperature chemicals. Several factors, including the physical properties of the sterilizing agents and whether all of the instruments' surfaces can be adequately cleaned, can cause significant variations in the reliability and effectiveness of the sterilization processes. Instruments exposed to heat-based sterilization processes pose the lowest probability of transmitting diseases between patients. Heat can conduct through many different types of materials and can destroy microorganisms embedded under layers of patient debris. Studies have demonstrated, however, that--unlike heat--low-temperature chemicals require direct contact with the microorganisms to be effective. Moreover, the complex designs of some instruments can adversely affect the low-temperature sterilization processes' outcomes by hindering cleaning and preventing the flow of low-temperature chemicals to all of the instruments' contaminated surfaces. This article will explore the differences between heat-based and low-temperature chemical processes to help health care providers minimize the risk of cross-infection.Keywords
This publication has 31 references indexed in Scilit:
- An Evaluation of the AbTox Plazlyte Sterilization SystemInfection Control & Hospital Epidemiology, 1997
- Sterilization of endoscopes; sanitation; nail polish; surgical attire; cloth hats; autotransfusion devicesAORN Journal, 1997
- Quality of water in washer-disinfectorsJournal of Hospital Infection, 1995
- FDA Labeling Requirements for Disinfection of Endoscopes: A CounterpointInfection Control & Hospital Epidemiology, 1995
- Evaluation of the Steris System 1 peracetic acid endoscope processorJournal of Hospital Infection, 1995
- Downsizing; counting multipack suture; processing endoscopes; cross training; standardizing OR countsAORN Journal, 1994
- STERIS SYSTEM 1 in GermanyInfection Control & Hospital Epidemiology, 1994
- APIC guideline for infection prevention and control in flexible endoscopyAmerican Journal of Infection Control, 1994
- The Difficulty of Reprocessing Reusable Rigid Endoscopic Instruments: Are Disposables the Solution?Journal of Gynecologic Surgery, 1994
- Biological Indicators for a Liquid Chemical Sterilizer A Solution to the Instrument Reprocessing Problem?Infection Control & Hospital Epidemiology, 1993