Effect of pore size on the peel strength of attachment of fibrous tissue to porous‐surfaced implants
- 1 September 1982
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 16 (5), 571-584
- https://doi.org/10.1002/jbm.820160505
Abstract
Twenty-four rectangular metal plates were fabricated with surface regions in three different pore size ranges (5–20 μm, 20–50 μm, 50–200 μm). The plates were implanted into the dorsal subcutaneous tissue of 12 adult mongrel dogs for periods of 4, 8, 12, and 16 weeks. After animal sacrifice, the fibrous tissue which adhered to the porous-surfaced regions of each plate was mechanically peeled off to give an indication of the strength of tissue attachment. The tissue was examined by both transmitted light and scanning electron microscopy. At each time period, the tissue that contacted the porous regions was found to be collagenized fibroconnective tissue. The mechanical tests indicated an increasing strength of tissue attachment with increasing implantation time and pore size range. The largest pore size range of approximately 50–200 μm produced a mean peel strength of attachment of 27.5 g/mm at the 16-week period.This publication has 14 references indexed in Scilit:
- Radiographic and Morphologic Studies of Load-Bearing Porous-Surfaced Structured ImplantsClinical Orthopaedics and Related Research, 1981
- The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of BoneClinical Orthopaedics and Related Research, 1980
- The Effect of Porous Surface Configuration on the Tensile Strength of Fixation of Implants by Bone IngrowthClinical Orthopaedics and Related Research, 1980
- The Porous Endocardial ElectrodePacing and Clinical Electrophysiology, 1979
- Arterio-venous shunt with percutaneous leads in calves for long-termin vivotesting of blood-contact materialsJournal of Biomedical Materials Research, 1978
- A high‐modulus polymer for porous orthopedic implants: Biomechanical compatibility of porous implantsJournal of Biomedical Materials Research, 1978
- Biological anchoring of acrylic tooth implants in the dog using enriched collagen solutionsArchives of Oral Biology, 1978
- A percutaneous implant using a porous metal surface coating for adhesion to bone and a velour covering for soft tissue attachment: Results of trials in pigsJournal of Biomedical Materials Research, 1977
- Porous methyl methacrylate as an implant materialJournal of Biomedical Materials Research, 1972
- Some chemical and biological characteristics of a new collagen–polymer compound materialJournal of Biomedical Materials Research, 1969