Comparison of Doppler derived haemodynamic variables and simultaneous high fidelity pressure measurements in severe pulmonary hypertension.
Open Access
- 1 October 1994
- Vol. 72 (4), 384-389
- https://doi.org/10.1136/hrt.72.4.384
Abstract
OBJECTIVE--To assess relations between right ventricular pressure measured with a high fidelity transducer tipped catheter and the characteristics of tricuspid regurgitation recorded with Doppler echocardiography. DESIGN--A prospective non-randomised study of patients with severe pulmonary hypertension referred for consideration of lung transplantation. SETTING--A tertiary referral centre for cardiac and pulmonary disease, with facilities for invasive and non-invasive investigation, and assessment for heart and heart-lung transplantation. PATIENTS--10 patients with severe pulmonary hypertension being considered for lung transplantation. ENDPOINTS--Peak right ventricular, pulmonary artery, and right atrial pressures; peak positive and negative right ventricular dP/dt; peak Doppler right ventricular-right atrial pressure drop; Doppler derived peak positive and negative right ventricular dP/dt; and time intervals of Q to peak right ventricular pressure and to peak positive and negative right ventricular dP/dt. RESULTS--The mean (SD) pulmonary artery systolic pressure was 109 (29) mm Hg. The peak Doppler right ventricular-right atrial pressure drop underestimated peak right ventricular pressure by 38 (21) mm Hg, and by 21 (18) mm Hg when the Doppler value was added to the measured right atrial pressure (P values < 0.05). This discrepancy was greater for higher pulmonary artery pressures. The timing of peak right ventricular pressure differed, with the Doppler value consistently shorter (mean difference 16 ms, P < 0.05). Values of peak positive and negative right ventricular dP/dt and the time intervals Q-peak positive right ventricular dP/dt and pulmonary closure to the end of the pressure pulse differed between the two techniques in individual patients, but not in a consistent or predictable way. CONCLUSIONS--Doppler echocardiography significantly underestimates the peak right ventricular pressure and the time interval to peak right ventricular pressure in pulmonary hypertension, particularly when severe. These differences may be related to orifice geometry. Digitisation of Doppler records of tricuspid regurgitation provides useful semiquantitative estimates of absolute values and timing of peak positive and negative right ventricular dP/dt. Clinically significant differences may exist, however, and must be considered in individual patients.Keywords
This publication has 18 references indexed in Scilit:
- Left ventricular filling characteristics in pulmonary hypertension: a new mode of ventricular interactionHeart, 1992
- Assessment of the peak tricuspid regurgitant velocity from the dynamics of retrograde flowInternational Journal of Cardiology, 1992
- Errors in pressure gradient measurement by continuous wave Doppler ultrasound: Type, size and age effects in bioprosthetic aortic valvesJournal of the American College of Cardiology, 1991
- Review of hydrodynamic principles for the cardiologist: Applications to the study of blood flow and jets by imaging techniquesJournal of the American College of Cardiology, 1988
- When should doppler-determined valve area be better than the Gorlin formula?: Variation in hydraulic constants in low flow statesJournal of the American College of Cardiology, 1987
- The effect of chronic pulmonary hypertension on left ventricular size, function, and interventricular septal motionAmerican Heart Journal, 1987
- Doppler echocardiography assessment of impaired left ventricular filling in patients with right ventricular pressure overload due to primary pulmonary hypertensionJournal of the American College of Cardiology, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Continuous wave doppler determination of right ventricular pressure: A simultaneous Doppler-catheterization study in 127 patientsJournal of the American College of Cardiology, 1985
- Noninvasive estimation of right ventricular systolic pressure by Doppler ultrasound in patients with tricuspid regurgitation.Circulation, 1984