Abstract
Immunoaffinity chromatography (IAC) provides a selective method for sample preparation prior to high-performance liquid chromatography (HPLC) or gas chromatography (GC). Five different support materials were tested for their suitability with regard to IAC of herbicides (s-triazines). Three gels showing low (0-10 %) nonspecific s-triazine adsorption were used as affinity supports (Beaded cellulose ONB-carbonate A, LiChroprep hydrazide tentacle gel and LiChroprep azlactone gel). A monoclonal antibody (K4E7), directed against atrazine, was covalently coupled to the gels. High antibody immobilization rates (100 %) were obtained with the beaded cellulose gel in comparison to the other gels (60-70 %). Subsequently the IAC columns were loaded with triazine solutions. Glycine-HCl 0.2 mol/L, pH 2.2 yielded the best results for the elution of the bound triazines from the beaded cellulose IAC columns (70-100 %). Both the hydrazide tentacle and the azlactone IAC columns showed lower elution rates (60-80 %).Keywords
This publication has 14 references indexed in Scilit:
- On-line sample treatment for or via column liquid chromatographyJournal of Chromatography A, 1994
- Immunoaffinity Chromatographic Purification of Russell′s Viper Venom Factor X Activator Using Elution in High Concentrations of Magnesium ChlorideProtein Expression and Purification, 1993
- Purification of grapevine flavescence dorée MLO (Mycoplasma-like organism) by immunoaffinityCurrent Microbiology, 1993
- Purification and analysis of drug residues in urine samples by on-line immunoaffinity chromatography/high-performance liquid chromatography/continuous-flow fast-atom-bombardment mass spectrometryAnalytical Chemistry, 1993
- A new monoclonal antibody for the sensitive detection of atrazine with immunoassay in microtiter plate and dipstick formatJournal of Agricultural and Food Chemistry, 1993
- Immunoadsorption: Strategies for Antigen Elution and Production of Reusable AdsorbentsBiotechnology Progress, 1992
- Bead cellulose derivatives as supports for immobilization and chromatographic purification of proteinsJournal of Chromatography A, 1991
- Immunoaffinity precolumn for selective sample pretreatment in column liquid chromatography: Immunoselective desorptionChromatographia, 1991
- Immobilization of glycoconjugates by their oligosaccharides: Use of hydrazido-derivatized matricesAnalytical Biochemistry, 1990
- Improved enzyme immunoassay for the analysis of s‐triazines in water samplesFood and Agricultural Immunology, 1989