Tests on superconducting helix resonators

Abstract
A niobium helix‐resonator cavity close to the frequency suitable for a heavy‐ion accelerator has been subject to an 8‐week test, including 323 h at full power (axial electric field Eax>2.5 MV/m). The cavity, with an anodically deposited protective film of Nb2O5, had a high Q and supported high fields without deterioration over the whole period during which it was subject to a moderate internally generated x‐ray dose. Properties were found to be stable against considerable thermal cycling and exposure to air. Measurement of emitted x‐ray maximum energy allowed an independent corroboration of the field measurement calibration.

This publication has 4 references indexed in Scilit: