Intersubject Variability of Foveal Cone Photoreceptor Density in Relation to Eye Length
Open Access
- 1 December 2010
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Opthalmology & Visual Science
- Vol. 51 (12), 6858-6867
- https://doi.org/10.1167/iovs.10-5499
Abstract
Purpose.: Adaptive optics scanning laser ophthalmoscopy (AOSLO) under optimized wavefront correction allows for routine imaging of foveal cone photoreceptors. The intersubject variability of foveal cone density was measured and its relation to eye length evaluated. Methods.: AOSLO was used to image 18 healthy eyes with axial lengths from 22.86 to 28.31 mm. Ocular biometry and an eye model were used to estimate the retinal magnification factor. Individual cones in the AOSLO images were labeled, and the locations were used to generate topographic maps representing the spatial distribution of density. Representative retinal (cones/mm2) and angular (cones/deg2) cone densities at specific eccentricities were calculated from these maps. Results.: The entire foveal cone mosaic was resolved in four eyes, whereas the cones within 0.03 mm eccentricity remained unresolved in most eyes. The preferred retinal locus deviated significantly (P < 0.001) from the point of peak cone density for all except one individual. A significant decrease in retinal density (P < 0.05) with increasing axial length was observed at 0.30 mm eccentricity but not closer. Longer, more myopic eyes generally had higher angular density near the foveal center than the shorter eyes, but by 1°, this difference was nullified by retinal expansion, and so angular densities across all eyes were similar. Conclusions.: The AOSLO can resolve the smallest foveal cones in certain eyes. Although myopia causes retinal stretching in the fovea, its effect within the foveola is confounded by factors other than cone density that have high levels of intersubject variability.Keywords
This publication has 52 references indexed in Scilit:
- Compact adaptive optics line scanning ophthalmoscopeOptics Express, 2009
- Open-loop control of a MEMS deformable mirror for large-amplitude wavefront controlJournal of the Optical Society of America A, 2007
- Voronoi analysis uncovers relationship between mosaics of normally placed and displaced amacrine cells in the thraira retinaNeuroinformatics, 2007
- Dynamic visual stimulus presentation in an adaptive optics scanning laser ophthalmoscope.2005
- Eye Shape in Emmetropia and MyopiaInvestigative Opthalmology & Visual Science, 2004
- The Effect of Myopic Axial Elongation and Posture on the Pulsatile Ocular Blood Flow in Young Normal SubjectsOptometry and Vision Science, 2002
- Human Corneal Thickness and Its Impact on Intraocular Pressure MeasuresSurvey of Ophthalmology, 2000
- The role of neural and optical factors in limiting visual resolution in myopiaVision Research, 1998
- Differences in the accommodation stimulus response curves of adult myopes and emmetropesOphthalmic and Physiological Optics, 1998
- Supernormal vision and high-resolution retinal imaging through adaptive opticsJournal of the Optical Society of America A, 1997