Low-Dose Spiral Computed Tomography of the Thorax
- 1 February 1998
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 33 (2), 68-73
- https://doi.org/10.1097/00004424-199802000-00002
Abstract
This study was conducted to determine whether significant reduction in radiation dose (250 mAs-->50 mAs), in chest computed tomography (CT) using volume acquisition affects image quality or the detectability of pathologic findings in the lung and mediastinum. Phantom studies were conducted to evaluate resolution and noise level, then a patient study was then done. Fifty consecutive patients (10 normal and 40 abnormal) cases were examined. After a scan (250 mAs, 120OkVp) of the entire thorax, five additional slices (50 mAs, 120kVp) at the level of the abnormality were obtained. Three independent observers evaluated the visibility of normal lung and mediastinal structures, as well as image noise. The mean score was compared between the standard and low doses. In a second study, an independent evaluation of the presence or absence of pathologic findings was made by four observers. Lucite phantom studies demonstrated diminished low-contrast resolution and increased noise level for the low-dose technique. Observers assessed more noise in the low-dose images (P < 0.001). The normal structures were judged to be more visible with standard dose (P < 0.01), but the magnitude of the judged differences was small especially in the lung. No differences were found in the detection of lung and mediastinal abnormalities (P > 0.10). The low-dose technique was effective in demonstrating pathologic findings for the lung and mediastinum. Low-dose spiral CT should be considered as a viable alternative to standard-dose spiral CT.Keywords
This publication has 18 references indexed in Scilit:
- Chronic infiltrative lung disease: comparison of diagnostic accuracies of radiography and low- and conventional-dose thin-section CT.Radiology, 1994
- Radiation dose reduction in CT of the pediatric pelvis.Radiology, 1994
- Merrill C. Sosman Lecture. The practice of radiology by nonradiologists: cost, quality, and utilization issues.American Journal of Roentgenology, 1994
- Pulmonary nodules: detection with thick-section spiral CT versus conventional CT.Radiology, 1993
- High-resolution CT of the chest: radiation dose.American Journal of Roentgenology, 1993
- Low-dose CT and inflammatory disease of the paranasal sinusesNeuroradiology, 1991
- Radiation dose reduction in pediatric CTPediatric Radiology, 1986
- National CT use and radiation exposure: United States 1983American Journal of Roentgenology, 1985
- The effect of mAs variation upon computed tomography image quality as evaluated by in vivo and in vitro studies.Radiology, 1981
- New techniques for CT-guided biopsiesAmerican Journal of Roentgenology, 1979