An analysis of fast imaging sequences with steady‐state transverse magnetization refocusing
- 1 February 1988
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 6 (2), 175-193
- https://doi.org/10.1002/mrm.1910060206
Abstract
Recently, several groups have proposed and demonstrated the use of rapid imaging methods, using short pulse repetition times and gradient-reversal echoes. Here, we analyze the behavior of the magnetization and the resulting image contrasts in such sequences for the case where the pulse repetition time TR is of the order of, or shorter than, the transverse relaxation time T2, and the transverse magnetization is not destroyed between phase-encoding cycles. Exact analytical expressions describing the signal evolution between the pulses are derived, taking into account the effects of resonance offsets and flip angles, and examining the influence of constant-phase or alternate-phase RF pulse trains. It is shown that for typical imaging sequences two distinct echo signals will develop between pulses, which may have a detrimental effect on image quality if they partially overlap within the sampling window. It is shown that artifact-free images can be obtained only if the two echo signals overlap precisely, which seems technically close to impossible to achieve, or if they are sufficiently separated in time to allow sampling of only one of the signals. © 1988 Academic Press, Inc.Keywords
This publication has 10 references indexed in Scilit:
- T2‐weighted contrasts in rapid low flip‐angle imagingMagnetic Resonance in Medicine, 1987
- Transverse coherence in rapid FLASH NMR imagingJournal of Magnetic Resonance (1969), 1987
- Three second clinical NMR images using a gradient recalled acquisition in a study state mode (GRASS)Magnetic Resonance Imaging, 1986
- Improved formulae for signal amplitudes in repeated NMR sequences: Applications in NMR imagingMagnetic Resonance in Medicine, 1986
- FLASH imaging. Rapid NMR imaging using low flip-angle pulsesJournal of Magnetic Resonance (1969), 1986
- A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1–100 MHz: Dependence on tissue type, NMR frequency, temperature, species, excision, and ageMedical Physics, 1984
- Spin warp NMR imaging and applications to human whole-body imagingPhysics in Medicine & Biology, 1980
- Image formation by nuclear magnetic resonance: The sensitive-point methodJournal of Applied Physics, 1976
- Phase and intensity anomalies in fourier transform NMRJournal of Magnetic Resonance (1969), 1971
- Application of Fourier Transform Spectroscopy to Magnetic ResonanceReview of Scientific Instruments, 1966