Effect of Variation of Tidal Volume on Size of Physiological Dead Space in Dogs
- 1 July 1956
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 9 (1), 30-32
- https://doi.org/10.1152/jappl.1956.9.1.30
Abstract
The size of the lung dead space, measured by substituting arterial for alveolar Pco2 in the Bohr equation, has been found to vary directly with the size of the tidal volume in anesthetized dogs. Simultaneous measurement of the dead space by this technique and by Pappenheimer's technique revealed that 'alveolar' CO2 tension measured by the latter was consistently lower than the arterial CO2 tension. Thus, one of the two assumptions necessary for measurement of a constant, isosaturation dead space did not prove correct. This finding, plus the linear relationship between PeCOCO2 and i/VT, indicates that the dead space equals a constant plus an amount which varies directly in magnitude with the size of the tidal volume. Submitted on December 27, 1955Keywords
This publication has 3 references indexed in Scilit:
- Components of the Respiratory Dead Space and Their Variation With Pressure Breathing and With Bronchoactive DrugsJournal of Applied Physiology, 1955
- ANALYZER FOR ACCURATE ESTIMATION OF RESPIRATORY GASES IN ONE-HALF CUBIC CENTIMETER SAMPLESJournal of Biological Chemistry, 1947
- A DIRECT METHOD FOR DETERMINATION OF OXYGEN AND CARBON DIOXIDE TENSIONS IN BLOODJournal of Biological Chemistry, 1945