False-Negative Results in Nucleic Acid Amplification Tests—Do We Need to Routinely Use Two Genetic Targets in all Assays to Overcome Problems Caused by Sequence Variation?
- 1 January 2008
- journal article
- research article
- Published by Taylor & Francis in Critical Reviews in Microbiology
- Vol. 34 (2), 71-76
- https://doi.org/10.1080/10408410801960913
Abstract
Nucleic acid amplification tests (NAATs) have numerous advantages over traditional diagnostic techniques and so are now widely used by diagnostic laboratories for routine detection of infectious agents. However, there is some concern over the increasing numbers of reports of NAAT false-negative results caused by sequence variation. Highly conserved NAAT target sequences have been reported for many organisms, yet sequence-related problems continue to be observed in commercial and in-house assays targeting a broad range of microbial pathogens. In light of these ongoing problems, it may be time to consider the use of two genetic targets in NAAT methods to reduce the potential for sequence-related false-negative results.Keywords
This publication has 30 references indexed in Scilit:
- A new genetic variant of Chlamydia trachomatisSexually Transmitted Infections, 2007
- Impact of Competitive Inhibition and Sequence Variation upon the Sensitivity of Malaria PCRJournal of Clinical Microbiology, 2007
- Real-Time PCR Diagnostics Failure Caused by Nucleotide Variability within Exon 4 of the Human Cytomegalovirus Major Immediate-Early GeneJournal of Clinical Microbiology, 2007
- Genetic variants of parvovirus B19 identified in the United Kingdom: Implications for diagnostic testingJournal of Clinical Virology, 2006
- Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory TestingClinical Microbiology Reviews, 2006
- Specific andSensitive Detection of Neisseria gonorrhoeae in ClinicalSpecimens by Real-Time PCRJournal of Clinical Microbiology, 2005
- Detection and Differentiation of Human Parvovirus Variants by Commercial Quantitative Real-Time PCR TestsJournal of Clinical Microbiology, 2004
- Comparison of a Duplex Quantitative Real-Time PCR Assay and the COBAS Amplicor CMV Monitor Test for Detection of CytomegalovirusJournal of Clinical Microbiology, 2004
- Evaluation of a TaqMan PCR Assay To Detect Rabies Virus RNA: Influence of Sequence Variation and Application to Quantification of Viral LoadsJournal of Clinical Microbiology, 2004
- Failure To Genotype Herpes Simplex Virus by Real-Time PCR Assay and Melting Curve Analysis Due to Sequence Variation within Probe Binding SitesJournal of Clinical Microbiology, 2003