Evolution and prognostic impact of low flow after transcatheter aortic valve replacement
- 21 May 2015
- Vol. 101 (15), 1196-1203
- https://doi.org/10.1136/heartjnl-2014-307067
Abstract
Objective Low flow (LF), defined as stroke volume index (SVi) 2, prior to the procedure has been recently identified as a powerful independent predictor of early and late mortality in patients undergoing transcatheter aortic valve replacement (TAVR). The objectives of this study were to determine the evolution of SVi following TAVR and to assess the determinants and impact on mortality of early postprocedural SVi (EP-SVi). Methods We retrospectively analysed the clinical, Doppler echocardiographic and outcome data prospectively collected in 255 patients who underwent TAVR. Echocardiograms were performed before (baseline), within 5 days after procedure (early post procedure) and 6 months to 1 year following TAVR (late post procedure). Results Patients with EP-SVi 2 (n=138; 54%) had increased mortality (HR 1.97, p=0.003) compared with those with EP-SVi ≥35 mL/m2 (n=117; 46%). Furthermore, patients with baseline SVi (B-SVi) 2 and EP-SVI ≥35 mL/m2, that is, normalised flow, had better survival (HR 0.46, p=0.03) than those with both B-SVi and EP-SVi 2, that is, persistent LF, and similar survival compared with those with both B-SVi and EP-SVi ≥35 mL/m2, that is, maintained normal flow. In a multivariable model analysis, EP-SVi was independently associated with increased risk of mortality (HR 1.41 per 10 mL/m2 decrease, p=0.03). The preprocedural/intraprocedural factors associated with lower EP-SVi were lower B-SVi (standardised β [β] 0.36, pConclusions The measurement of EP-SVi is useful to assess the immediate haemodynamic benefit of TAVR and to predict the risk of late mortality.Keywords
This publication has 25 references indexed in Scilit:
- Clinical outcomes of patients with low-flow, low-gradient, severe aortic stenosis and either preserved or reduced ejection fraction undergoing transcatheter aortic valve implantationEuropean Heart Journal, 2013
- Impact of Low Flow on the Outcome of High-Risk Patients Undergoing Transcatheter Aortic Valve ReplacementJournal of the American College of Cardiology, 2013
- Predictors of Mortality and Outcomes of Therapy in Low-Flow Severe Aortic StenosisCirculation, 2013
- Low-Flow, Low-Gradient Aortic Stenosis With Normal and Depressed Left Ventricular Ejection FractionJournal of the American College of Cardiology, 2012
- Outcome of Patients With Aortic Stenosis, Small Valve Area, and Low-Flow, Low-Gradient Despite Preserved Left Ventricular Ejection FractionJournal of the American College of Cardiology, 2012
- Transcatheter Aortic Valve Implantation in Patients With Low-Flow, Low-Gradient Aortic StenosisJACC: Cardiovascular Interventions, 2012
- Clinical Outcome in Asymptomatic Severe Aortic StenosisJournal of the American College of Cardiology, 2012
- Comparison Between Transcatheter and Surgical Prosthetic Valve Implantation in Patients With Severe Aortic Stenosis and Reduced Left Ventricular Ejection FractionCirculation, 2010
- Transcatheter aortic valve implantation for treatment of patients with degenerated aortic bioprostheses—valve‐in‐valve techniqueCatheterization and Cardiovascular Interventions, 2010
- Paradoxical Low-Flow, Low-Gradient Severe Aortic Stenosis Despite Preserved Ejection Fraction Is Associated With Higher Afterload and Reduced SurvivalCirculation, 2007