Lung function in silicosis
- 1 February 1992
- journal article
- Published by Springer Nature in Internationales Archiv für Arbeitsmedizin
- Vol. 63 (6), 387-391
- https://doi.org/10.1007/bf00386933
Abstract
In order to assess the effect of silicosis on lung function, 61 gold miners with radiological silicosis were compared with 61 controls. Each pair was matched for age, dust exposure, and smoking habits. A full range of lung function tests was performed, and with two exceptions the results showed no significant differences between the two groups. The exceptions are the slope of the alveolar plateau (phase 3) and he closing volume, for which the silicotic cases had significantly higher values. The reason for the higher readings in the silicotic patients remains unexplained.This publication has 1 reference indexed in Scilit:
- The Predictors of Emphysema in South African Gold Miners1–4American Review of Respiratory Disease, 1987