Performance of a new gadolinium‐based intravascular contrast agent in free‐breathing inversion‐recovery 3D coronary MRA

Abstract
In three‐dimensional (3D) coronary magnetic resonance angiography (MRA), the in‐flow contrast between the coronary blood and the surrounding myocardium is attenuated as compared to thin‐slab two‐dimensional (2D) techniques. The application of a gadolinium (Gd)‐based intravascular contrast agent may provide an additional source of signal and contrast by reducing T1blood and supporting the visualization of more distal or branching segments of the coronary arterial tree. In six healthy adults, the left coronary artery (LCA) system was imaged pre‐ and postcontrast with a 0.075‐mmol/kg bodyweight dose of the intravascular contrast agent B‐22956. For imaging, an optimized free‐breathing, navigator‐gated and ‐corrected 3D inversion recovery (IR) sequence was used. For comparison, state‐of‐the‐art baseline 3D coronary MRA with T2 preparation for non‐exogenous contrast enhancement was acquired. The combination of IR 3D coronary MRA, sophisticated navigator technology, and B‐22956 allowed for an extensive visualization of the LCA system. Postcontrast, a significant increase in both the signal‐to‐noise ratio (SNR; 46%, P < 0.05) and contrast‐to‐noise ratio (CNR; 160%, P < 0.01) was observed, while vessel sharpness of the left anterior descending (LAD) artery and the left coronary circumflex (LCX) were improved by 20% (P < 0.05) and 18% (P < 0.05), respectively. Magn Reson Med 49:115–121, 2003.