Radiation Damage Induced Dose Rate Non-Linearity in an N-Type Silicon Detector
- 1 January 1984
- journal article
- research article
- Published by Taylor & Francis in Acta Radiologica: Oncology
- Vol. 23 (6), 465-469
- https://doi.org/10.3109/02841868409136050
Abstract
Depth dose measurements in continuous cobalt radiation and pulsed roentgen rays were performed with non-irradiated and preirradiated detectors made of n-type silicon. A change in the relative signal at 15 cm depth of 5 to 10 per cent was found in pulsed roentgen ray fields when the detector was radiation damaged. Further experiments showed that the preirradiated detector had a superlinear dose response characteristic at high dose rates. A theoretic model was worked out and the non-linearity is explained by the properties of the recombination centers created during the preirradiation. The recombination centers are also responsible for the sensitivity drop after irradiation. At low dose rates in continuous radiation the non-linearity effect is not observed, which is in accordance with the theory. The theory in conjunction with our and other experimental results suggests that a p-silicon detector will remain linear also after heavy preirradiation.This publication has 10 references indexed in Scilit:
- Procedures in External Radiation Therapy Dosimetry with Electron and Photon Beams with Maximum Energies Between 1 and 50 MeV Recommendations by the Nordic Association of Clinical Physics (NACP)Acta Radiologica: Oncology, 1980
- Silicon diode detectors used in radiological physics measurements. Part II. Measurement of dosimetry data for high-energy photonsMedical Physics, 1977
- Silicon diode detectors used in radiological physics measurements. Part I: Development of an energy compensating shieldMedical Physics, 1977
- Measurement of γ-dose rates by n- and p-type semiconductor detectorsPhysica Status Solidi (a), 1975
- A tissue equivalent semiconductor detector for in-vivo dosimetryNuclear Instruments and Methods, 1972
- Instrument for Dose Rate Measurements in Gynaecologic Radiation TherapyActa Radiologica. Diagnosis, 1972
- Exposure Rate Measurements of X- and Gamma-rays With Silicon Radiation DetectorsHealth Physics, 1967
- The use of the Miniature Silicon Diode as a Radiation DosemeterPhysics in Medicine & Biology, 1966
- Steady-State Response of Silicon Radiation Detectors of the Diffused p-n Junction Type to X Rays. I: Photovoltaic Mode of OperationJournal of Research of the National Bureau of Standards Section A: Physics and Chemistry, 1964
- Radiation Dosimetry by Means of SemiconductorsActa Radiologica, 1962