ECG-Gated Three-dimensional Intravascular Ultrasound
- 4 November 1997
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 96 (9), 2944-2952
- https://doi.org/10.1161/01.cir.96.9.2944
Abstract
Background Automated systems for the quantitative analysis of three-dimensional (3D) sets of intravascular ultrasound (IVUS) images have been developed to reduce the time required to perform volumetric analyses; however, 3D image reconstruction by these nongated systems is frequently hampered by cyclic artifacts. Methods and Results We used an ECG-gated 3D IVUS image acquisition workstation and a dedicated pullback device in atherosclerotic coronary segments of 30 patients to evaluate (1) the feasibility of this approach of image acquisition, (2) the reproducibility of an automated contour detection algorithm in measuring lumen, external elastic membrane, and plaque+media cross-sectional areas (CSAs) and volumes and the cross-sectional and volumetric plaque+media burden, and (3) the agreement between the automated area measurements and the results of manual tracing. The gated image acquisition took 3.9±1.5 minutes. The length of the segments analyzed was 9.6 to 40.0 mm, with 2.3±1.5 side branches per segment. The minimum lumen CSA measured 6.4±1.7 mm 2 , and the maximum and average CSA plaque+media burden measured 60.5±10.2% and 46.5±9.9%, respectively. The automated contour-detection required 34.3±7.3 minutes per segment. The differences between these measurements and manual tracing did not exceed 1.6% (SDr =.97 to.99) were r =.99) were Conclusions ECG-gated acquisition of 3D IVUS image sets is feasible and permits the application of automated contour detection to provide reproducible measurements of the lumen and atherosclerotic plaque CSA and volume in a relatively short analysis time.Keywords
This publication has 31 references indexed in Scilit:
- Computerized assessment of coronary lumen and atherosclerotic plaque dimensions in three-dimensional intravascular ultrasound correlated with histomorphometryThe American Journal of Cardiology, 1996
- Structural and functional characterization of an intermediate stenosis with intracoronary ultrasound and Doppler: A case of “reverse Glagovian modeling”American Heart Journal, 1996
- Morphometric analysis in three-dimensional intracoronary ultrasound: An in vitro and in vivo study performed with a novel system for the contour detection of lumen and plaqueAmerican Heart Journal, 1996
- Usefulness of three-dimensional reconstruction for interpretation and quantitative analysis of intracoronary ultrasound during stent deploymentThe American Journal of Cardiology, 1996
- Mechanism of high-speed rotational atherectomy and adjunctive balloon angioplasty revisited by quantitative coronary angiography: Edge detection versus videodensitometryAmerican Heart Journal, 1995
- Mechanical scanning in intravascular ultrasound imaging: artifacts and driving mechanisms:European Journal of Ultrasound, 1995
- Effect of intracoronary ultrasound imaging on clinical decision makingAmerican Heart Journal, 1995
- Intracoronary ultrasound imaging: Intraobserver and interobserver variability of morphometric measurementsAmerican Heart Journal, 1994
- Assessment of normal and atherosclerotic arterial wall thickness with an intravascular ultrasound imaging catheterAmerican Heart Journal, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986