Abstract
Contrast between blood and myocardium in standard turbo gradient echo MR techniques (TFE) used routinely in clinical practice is mainly caused by unsaturated inflowing blood. Steady‐state free precession (SSFP) has excellent contrast even in the absence of inflow effects. In 45 subjects cardiac cine loops in two long axis projections were acquired using TFE and compared with SSFP. A visual score (range 0 worst – 3 best) was assigned for endocardial border delineation for six myocardial segments in two long axis views. Endocardial border delineation score for TFE was 1.3 ± 0.3 per segment and 2.4 ± 0.3 for SSFP (P < 0.0001). Signal intensity blood/signal intensity myocardium was 1.5 ± 0.4 at enddiastole and 1.4 ± 0.3 at systole for TFE and 3.5 ± 1.1 and 3.2 ± 1.3 for SSFP, respectively (P < 0.0001). SSFP increases contrast between blood and myocardium more than twofold, resulting in an improved endocardial border definition. This may reduce variability for the determination of cardiac volumes and ejection fraction. J. Magn. Reson. Imaging 2001;14:362–367. ©2001 Wiley‐Liss, Inc.Keywords
This publication has 20 references indexed in Scilit:
- Utility of Fast Cine Magnetic Resonance Imaging and Display for the Detection of Myocardial Ischemia in Patients Not Well Suited for Second Harmonic Stress EchocardiographyCirculation, 1999
- Einfluß der Bildqualität auf die Genauigkeit der nichtinvasiven Ischämiediagnostik mit der Dobutamin-Streßmagnetresonanztomographie im Vergleich zur Dobutamin-StreßechokardiographieClinical Research in Cardiology, 1999
- Noninvasive Diagnosis of Ischemia-Induced Wall Motion Abnormalities With the Use of High-Dose Dobutamine Stress MRICirculation, 1999
- Magnetic resonance imaging during dobutamine stress for detection and localization of coronary artery disease. Quantitative wall motion analysis using a modification of the centerline method.Circulation, 1994
- Magnetic resonance imaging during dobutamine stress in coronary artery diseaseThe American Journal of Cardiology, 1992
- Interstudy reproducibility of dimensional and functional measurements between cine magnetic resonance studies in the morphologically abnormal left ventricleAmerican Heart Journal, 1990
- Normal left ventricular dimensions and function: interstudy reproducibility of measurements with cine MR imaging.Radiology, 1990
- Measurement of right and left ventricular volumes in healthy individuals with cine MR imaging.Radiology, 1987
- Ejection fraction determination by MR imaging: comparison with left ventricular angiography.Radiology, 1986
- DIMENSIONAL ACCURACY OF MAGNETIC RESONANCE IN STUDIES OF THE HEARTThe Lancet, 1985