Stable isotopes and the international system of units
- 4 July 2001
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 15 (15), 1270-1273
- https://doi.org/10.1002/rcm.328
Abstract
It is now over 60 years since Nier built the first isotope ratio mass spectrometer. The introduction of continuous-flow techniques heralded a huge expansion in the use of stable isotopes in biomedical and environmental sciences, yet there is no consensus on the appropriate units, especially in the biomedical field. Most isotope ratio mass spectrometry (IRMS) instruments calculate isotopic abundance in terms of delta notation (δ, ‰, per mil), which is a convention determined by geochemistry, because most of the original IRMS instruments were developed in isotope geochemistry laboratories to measure natural abundance variations. Delta units are not SI units. This paper considers the appropriate units for studies using stable isotopes based on the International System of Units (SI). The SI base unit for concentration is the mol, from which atom fraction and mol fraction are derived. The units of stable isotope abundance, atom % and mol %, are the atom and mol fractions expressed as percentages. Atom % excess and mol % excess are the SI units of enrichment and are to be recommended for use in tracer studies. Copyright © 2001 John Wiley & Sons, Ltd.Keywords
This publication has 16 references indexed in Scilit:
- Sulphur isotope data consistency improvedNature, 1998
- Reporting of relative sulfur isotope-ratio data (Technical Report)Pure and Applied Chemistry, 1997
- High-precision continuous-flow isotope ratio mass spectrometryMass Spectrometry Reviews, 1997
- New guidelines for reporting stable hydrogen, carbon, and oxygen isotope-ratio dataGeochimica et Cosmochimica Acta, 1996
- Discontinuance of SMOW and PDBNature, 1995
- Reporting of stable hydrogen, carbon, and oxygen isotopic abundances (Technical Report)Pure and Applied Chemistry, 1994
- Preliminary13C measurements using a gas chromatograph interfaced to an isotope ratio mass spectrometerJournal of Mass Spectrometry, 1985
- Interfacing an automatic elemental analyser with an isotope ratio mass sepectrometer: the potential for fully automated total nitrogen and nitrogen-15 analysisThe Analyst, 1983
- Improvements in Mass Spectrometers for the Measurement of Small Differences in Isotope Abundance RatiosReview of Scientific Instruments, 1950
- A Mass Spectrometer for Routine Isotope Abundance MeasurementsReview of Scientific Instruments, 1940