In vivo biodegradability and biocompatibility evaluation of novel alanine ester based polyphosphazenes in a rat model

Abstract
Amino acid ester substituted polyphosphazenes are attractive candidates for various biomedical applications because of their biocompatibility, controllable hydrolytic degradation rates, and nontoxic degradation products. In this study, the biocompatibility of three L-alanine ethyl ester functionalized polyphosphazenes was evaluated in a subcutaneous rat model. The polymers used in the study were poly[bis(ethylalanato)phosphazene] (PNEA), poly[(50% ethylalanato) (50% methylphenoxy) phosphazene] (PNEA50mPh50), and poly[(50% ethylalanato)(50% phenyl phenoxy) phosphazene] (PNEA50PhPh50). Polymer disks of diameter 7.5 mm were prepared by a solvent evaporation technique and were implanted subcutaneously in rats. After 2, 4, and 12 weeks, the polymer along with the surrounding tissues were excised, prepared, and viewed by light microscopy to evaluate the tissue responses of the implanted polymers. The tissue responses were classified as minimal, mild, or moderate, based on a biocompatibility scheme developed in our laboratory. Minimal inflammation was characterized by the presence of few neutrophils, erythrocytes, and lymphocytes; mild response was characterized by the predominant presence of macrophages, fibroblasts, or giant cells; and moderate inflammation was characterized by the abundance of macrophages, giant cells, and by the presence of tissue exudates. The in vivo degradation profiles of the polymers at various time points were evaluated by gel permeation chromatography (GPC). PNEA and PNEA50mPh50 matrices elicited varying levels of tissue responses during the 12-week implantation period. At 2 weeks both polymers evoked a moderate response, and by 12 weeks the response was found to be mild. However, PNEA50PhPh50 elicited a mild response at the end of 2 weeks and demonstrated a further decreased inflammatory response after12 weeks. The in vivo degradation of the polymers was followed by determining the molecular weights of the explanted polymer disks. PNEA and PNEA50mPh50 disks showed significant decrease in molecular weight after 2 weeks of implantation. The molecular weights of PNEA and PNEA50mPh50 residues could not be determined by GPC after 12 weeks of implantation because of almost complete degradation. On the other hand the in vivo degradation of PNEA50PhPh50 was found to be slow, with a 63% loss in molecular weight in 12 weeks. Furthermore, this polymer maintained its shape and structure during the entire study. Thus, these polymers demonstrated excellent tissue compatibility and in vivo biodegradability and can be potential candidates for various biomedical applications. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006

This publication has 23 references indexed in Scilit: