Hemocompatibility, biocompatibility, inflammatory and in vivo studies of primary reference materials low‐density polyethylene and polydimethylsiloxane: A review
Top Cited Papers
- 1 January 2001
- journal article
- review article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 58 (5), 467-477
- https://doi.org/10.1002/jbm.1043
Abstract
In 1984, low‐density polyethylene (LDPE) and polymethylsiloxane (PDMS), two primary reference materials (PRM), were made available by the National Heart, Lung, and Blood Institute (NHLBI) as discriminatory tools for the validation of standardized and novel in vitro and in vivo tests in the evaluation of biomaterials. This article reviews the results and conclusions obtained by several studies investigating the hemocompatibility, in vitro biocompatibility, inflammatory response, and in vivo tissue reactions of these two reference materials. Variable results obtained with LDPE and PDMS in ex vivo hemocompatibility studies were attributed to the type of animal model used, the flow velocity of the circulating blood, the time of exposure, and the methodology used to measure blood cell adhesion or activation at the surface of the materials. In contrast, both the LDPE and PDMS appeared to be suitable reference materials when used in in vitro biocompatibility, inflammatory response, and in vivo studies. However, caution must be taken when interpreting the results, because gamma sterilization of these two materials as well as their origin (for example PDMS) are two critically important factors. In conclusion, we see a definite need for standardized hemocompatible parameters and better high‐quality hemocompatibility studies on PRM. This review also suggests other materials as potential PRM candidates, namely, Biomer® and Intramedic™ polyethylene. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 58: 467–477, 2001Keywords
This publication has 30 references indexed in Scilit:
- Flow cytometric study ofin vitro neutrophil activation by biomaterialsJournal of Biomedical Materials Research, 1999
- Protein adsorption and macrophage activation on polydimethylsiloxane and silicone rubberJournal of Biomaterials Science, Polymer Edition, 1996
- Factor XII fragment and kallikrein generation in plasma during incubation with biomaterialsJournal of Biomedical Materials Research, 1994
- A canine ex vivo shunt for isotopic hemocompatibility evaluation of a NHLBI DTB primary reference material and of a IUPAC reference materialJournal of Biomaterials Science, Polymer Edition, 1994
- Protein adsorption studies on 'standard' polymeric materialsJournal of Biomaterials Science, Polymer Edition, 1993
- Cytocompatibility study of NHLBI primary reference materials using human endothelial cellsJournal of Biomaterials Science, Polymer Edition, 1992
- Platelet consumption by NHLBI reference materials and SilasticJournal of Biomedical Materials Research, 1991
- Fibroblast stimulation by monocytes cultured on protein adsorbed biomedical polymers. I. Biomer and polydimethylsiloxaneJournal of Biomedical Materials Research, 1991
- Acute and chronic canine ex vivo blood interactions with NHLBI-DTB Primary Reference MaterialsBiomaterials, 1989
- The interaction of blood components with PDMS(polydimethylsiloxane) and LDPE (low‐density polyethylene) in a baboon ex vivo arteriovenous shunt modelJournal of Biomedical Materials Research, 1985