Measurement of Nicotine in Plasma by High-Performance Liquid Chromatography

Abstract
A new procedure has been developed to measure nicotine in blood plasma by high-performance liquid chromatography (HPLC). Nicotine is extracted from plasma by elution with cholorform. Final determination is achieved by isocratic HPLC with ultraviolet detection. Twenty microliters of plasma extract is deluted over a silica column at a flow rate of 1.0 ml/min with a dioxane:isopropanol:NH4OH (80:3.0:0.4) mobile phase. The procedure is sensitive to 0.05 ug of nicotine per ml of plasma and is linear within the range of 0.05 to 10.0 ug/ml of plasma. When a known amount of nicotine was added to plasma, the concentration of nicotine measured averaged 99.9 + 3.9 (S.D.)% of the known concentration. The within-sample coefficient of variation was 3.9%