A Method for Surface Voltage Measurement of an Overhead Insulated Conductor
- 11 September 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456), 1-8
- https://doi.org/10.1109/tim.2020.3021803
Abstract
Surface voltage measurement of an insulated overhead conductor assumes importance for understanding corona, radio interference voltage and for design purposes. Surface voltage measurement of a bare overhead conductor is quite simple as a voltage divider can be directly connected. However, there are challenges in the measurement of surface voltage on an insulating surface of an insulated covered conductor using voltage dividers. In case of ac measurements, the capacitance parameter dominates in deciding the potential distribution. In this paper, it is demonstrated that the measuring system itself will alter the voltage division between the capacitance of the cylindrical insulated conductor and that of surrounding air acting as a capacitive divider. The voltage distribution is shown to be drastically influenced by the measuring system capacitance. In view of these issues, a novel experimental method is proposed for the measurement of surface voltage of an overhead insulated covered conductor. In general, the method can be applied to any cylindrical insulated conductor and for calibration of sensor based measurements. The proposed empirical method is tested by a validated simulation of the entire system and it is proven analytically. The radial voltage gradients are then estimated from measured surface voltages. The analytical, experimental and simulation results are in close conformity.Keywords
This publication has 17 references indexed in Scilit:
- Analysis of electric field influence on buildings under high‐voltage transmission linesIET Science, Measurement & Technology, 2016
- Implementation of a novel double-side technique for partial discharge detection and location in covered conductor overhead distribution networksMeasurement Science and Technology, 2015
- Feasibility study of a non-contact AC voltage measurement systemPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2015
- Calibrated Single-Contact Voltage Sensor for High-Voltage Monitoring ApplicationsIEEE Transactions on Instrumentation and Measurement, 2014
- Calculating the Surface Potential Gradient of Overhead Line ConductorsIEEE Transactions on Power Delivery, 2014
- Study on the field behavior at the contact point between a covered conductor and a dielectric solidPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2011
- Calibration of on-line partial discharge measuring system using Rogowski coil in covered-conductor overhead distribution networksIET Science, Measurement & Technology, 2011
- Design of Systems of Covered Overhead Conductors by Means of Electric Field CalculationIEEE Transactions on Power Delivery, 2005
- Design and application of aerial systems using insulated and covered wire and cableIEEE Transactions on Power Delivery, 1997